![Nordson EFD ValveMate 7140 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/nordson-efd/valvemate-7140/valvemate-7140_operating-manual_1704545019.webp)
19
Input/Output Connections
The 10 pin terminal strip includes a 5-24VDC and contact closure CC initiate
inputs. Outputs include an Alarm Out, End of Cycle EOC and a 24VDC courtesy
power.
5-24 INIT: Dispense initiate input activated with a 5-24VDC input voltage.
EOC OUT: End-of-cycle feedback
ALARM OUT: Circuit that closes when an alarm condition is present.
CC INIT: Dispense initiate input activated with a contact closure switch.
24VDC OUT: Courtesy output 24VDC, 100mA.
Note
: ALARM OUT and EOC (End-of-cycle) only function in RUN mode.