Appendix B,
Toµch
XP Controller (continued)
WAVE PARAMETERS screen on the Toµch XP controller (STROKE units set in microns)
Button
Description
CLOSE VOLTS
Sets the voltage to close the valve. The higher the voltage, the greater the sealing force
applied.
STROKE
Sets the tappet displacement in microns.
NOTE:
This parameter differs on the standard
Toµch
controller. Refer to “WAVE PARAMETERS
OPEN
Sets how fast the valve opens. The range is valve-dependent, but typically 200–500 µs.
CLOSE
Sets how fast the valve closes. The range is valve-dependent, but typically 200–2,000 µs.
When pressed on this screen, the Wave Profile icon opens the WAVE PROFILE screen, on
which you can select a different wave profile. Refer to “WAVE PROFILE Screen” on page 27
for details.
Toµch
XP WAVE PARAMETERS Screen
The WAVE PARAMETERS screen is used to adjust the parameters of a wave profile in order to fine-tune the
resulting material deposit. The graph on the screen provides a visual representation of a wave profile.
NOTES:
• On a
Toµch
XP controller, the STROKE value is set in microns.
• This screen is accessed in two ways: (1) by pressing the Wave Profile icon (
) on the HOME screen or (2) by
pressing the Wave Profile icon (
) on the WAVE PROFILE screen.
• Wave profiles are enabled on the WAVE PROFILE screen. Refer to “WAVE PROFILE Screen” on page 27.