781S Series Spray Valve

Prior to installing this valve, please read the 
associated reservoir and valve controller 
operating instructions to become familiar with 
the operation of all components of the spray 
system.

1. 

Connect the fluid supply line to valve.

2. 

Connect the fluid supply line to the reservoir.

3. 

Connect the control air hose and the nozzle 
air hose to corresponding outputs on 
solenoid block.

4. 

Fill reservoir by pouring fluid directly into 
tank liner or manufacturer’s bottle placed 

inside reservoir. Secure cover prior to setting 
pressure.

5. 

Set reservoir pressure to low for thin fluids 
and higher for thick fluids.

6. 

Using the Mode   button on the ValveMate 
controller, place the controller in the PURGE 

 mode. In PURGE 

 mode 

only, channels 

 and 

 can be 

selected   independently without nozzle air 
pressure.

7. 

Using the needle stroke control knob on 
the 781S valve, set the fluid flow rate to 
one or two drops per second. Check the 

flow rate by actuating the controller in the 
time override mode. Make valve stroke 
adjustments when the controller is off.

8. 

Set the nozzle air pressure on the nozzle to 
0.7 bar (10 psi) and actuate the controller. 
The valve will produce a fine spray. To 
change fluid flow, use the needle stroke 
control knob and / or reservoir pressure. To 
change nozzle air, use the nozzle air pressure 
regulator. Higher pressures will provide finer 
spray.

Installation

NOTE:

  The area of spray coverage is determined by the distance between the spray valve nozzle and the work surface. 

Refer to the charts on the back page to determine this distance.