1.
Mount valve with an EFD universal
valve mount (#7002VM) or other
fixture.
2.
Connect fluid supply line to valve.
3.
Connect the fluid supply line to
reservoir. The reservoir can accept
either 1/4” OD or 3/8” OD tubing
using #62518PT supplied.
4.
Connect valve control air hose to
ValveMate
™
controller (or other
pneumatic switch) used to control
valve open time.
5.
Choose a dispensing tip—small
tips (20 gauge) for low-viscosity
fluids and larger (14 gauge) for
higher viscosities.
6.
Fill reservoir by pouring fluid
directly into tank liner or
manufacturer’s bottle placed inside
reservoir. Secure cover prior to
setting pressure.
7.
Set reservoir pressure to low for thin
fluids and higher for thick fluids.
8.
Set the stroke control starting with
no more than 1/2 turn open from
closed position.
9.
Place a cup under the dispensing
tip and actuate the valve until fluid
lines, valve and dispensing tip are
free of air.
10
.
Set desired flow rate by adjusting
fluid reservoir pressure, diaphragm
stroke or changing dispensing tip.
Installation
Prior to installing this valve, please
read the associated reservoir and valve
controller operating instructions to
become familiar with the operation of all
components of the dispensing system.
POWER
RUN
SETUP
CYCLE
Test
Clear
Purge
Run
Setup
Program
Fast
Slow
Time Set
Steady
Fast
Slow
Time Set
STOP
Pressure
Time
®
A NORDSON COMPANY
To pressurize
To exhaust
Set desired deposit size by adjusting valve open
time. Refer to valve controller operating manual.
11
9
Open
Close
8
Air Output
ut
Exhaust
r
1
7
5
2
6
4
10
3