752V-HL Dispense Gun
2
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Getting Started
1.
Install the feed tube from the fluid reservoir to
the inlet fitting and tighten the compression nut
to secure. The location of the inlet fitting can
be changed by removing the two fluid body
retainer screws and fluid body. Follow the service
instructions to reinstall the fluid body with the inlet
fitting in the desired position.
2.
Apply air pressure to the fluid reservoir. Start with
a low setting of 1.4 bar (20 psi). If using an EFD
fluid reservoir, refer to the User’s Guide for further
instructions.
Introduction
The 752V-HL (#7021415) hand-operated dispense gun is a rugged, industrial, lever-actuated fluid dispensing valve.
The valve incorporates a quick change fluid body for fast and easy maintenance. The fluid inlet fitting for 1/4" OD
feed tubing and an assortment of dispensing tips are included.
Typical System Setup
3.
Install an appropriate size dispensing tip on
the outlet tip adapter. Use large tips for high
viscosity materials and small tips for low viscosity
materials.
4.
Press the hand lever to begin fluid flow. Release
the lever to stop fluid flow.
5.
To achieve the desired flow, change the size of
the dispensing tip or adjust the reservoir fluid
pressure.
#7020105
Hand-lever
valve stand
#7010004
1.0 liter tank
accommodates a one
pound bottle
#7002002
5-micron filter/regulator for
clean, dry filtered factory air
For dispensing with
cyanoacrylates, order #7016548
with coalescing filter.
Shutoff valve