Introduction

The 741MD-SS Series is simple to use and will 
operate many millions of cycles without maintenance.

The 741MD-SS is a pneumatically operated,
adjustable needle valve designed to apply precise
microdeposits of low to high viscosity fluids down 
to fractions of a microliter. It is ideal for automated
assembly processes that require small dispensing
tips (from 22 to 33 gauge). The 741MD-SS provides
exceptional control and the absolute minimum dead
fluid volume.

741MD-SS Series 
Dispense Valve

INSTALLATION GUIDE

Control 
air hose

Dispensing tip

Inlet fitting

Barrel adapter assembly

Barrel reservoir

Stroke reference ring

Fluid body

®

A NORDSON COMPANY

Electronic pdf files of EFD

®

manuals are also available at 

www.efd-inc.com/manuals.html.

USA: 800-556-3484 or +1-401-434-1680
Europe: 0800 585733 or +44 (0) 1582 666334
Asia: +86 (21) 5854 2345
[email protected] www.efd-inc.com

Содержание 741MD-SS Series

Страница 1: ...ire small dispensing tips from 22 to 33 gauge The 741MD SS provides exceptional control and the absolute minimum dead fluid volume 741MD SS Series Dispense Valve INSTALLATION GUIDE Control air hose Dispensing tip Inlet fitting Barrel adapter assembly Barrel reservoir Stroke reference ring Fluid body A NORDSON COMPANY Electronic pdf files of EFD manuals are also available at www efd inc com manuals...

Страница 2: ... when dis pensing medium to high viscosity mate rials see setup illustration 5 Attach the barrel adapter head to the barrel reservoir using air interconnect coupler to connect the barrel adapter assembly to the flexible air line 6 Install appropriate size EFD SafetyLok dispensing tip on the tip adapter Tighten the tip retaining nut fully to position the needle hub against the shoulder of the tip a...

Страница 3: ...ontrol Pad set time timer bypass display pressure psi bar TEACH program test cycle purge reset air input power input voltage selector air output to valve I O connector with alarm output 60 psi connector for optional foot pedal Rear Panel Pressure Time Toggle open closed Input air pressure at 70 psi 4 8 bar retracts the piston and needle from the needle seat in the dispensing tip permitting fluid f...

Страница 4: ...ositioned or reset to the zero mark use the following procedure A Remove the dispensing tip if installed B Turn the small knob counterclockwise one full turn C Turn the large knob clockwise until it stops If the zero on the reference ring does not line up with the index mark continue with the following steps D Loosen the small set screw located on the reference ring E Rotate reference ring until i...

Отзывы: