Operation
23
4.4.2.6 Needle XY Offset
To calculate the needle XY offset (Figure 4-13):
1. Click on the
Next
button to start Offsets for Dot Type 1.
2. Click on the
Yes
to reteach substrate corners on the mini service station on the back of
Conveyor Rail 2.
a. Use the position controls to move the camera crosshairs to the upper left substrate
corner and click on
Teach
.
b. Use the position controls to move the camera crosshairs to the lower right substrate
corner and click on
Teach.
3. Move the camera crosshairs to the dot locations and click on
Teach
.
4. Click on
Done
when finished with Dot Type 1 Vertical.
5. Repeat steps 1, 3 and 4 for all dot types in CW (clockwise) tilt direction.
6. Repeat steps 1, 3 and 4 for all dot types in CCW (counterclockwise) tilt direction.
You will return to the Machine Setup Window.
7. Click on
Exit
in the Machine Setup Window when all offsets are complete.
Figure 4-13 Alignment Dot 1 Dispensing Valve 1