Technical TABLE
Insert
S-18F
Material
Steel
Surface treatment
Heat resistant varnish
/ Decorative chrome
Weight of insert (kg)
100 kg
Draught system
Ignition air vent control
and air vent control
Combustion system
Clean burning
(Secondary combustion)
Combustion air consumption (m³/h) 9-25
Maximum fuel length (cm)
<40
Flue outlet
Top and rear
Flue collar (Ø mm)
Outer 150
*alternate versions exists due to nationa requirements
Flue gas temperature at flue
connector (°C)
320
Mass gas flow [g/s]
3,4
Draft at flue connector
recommended (Pa)
12-25
Data according to EN 13 229
Area of convection air vent under
insert (cm
2
)
250
Area of convection air vent over
insert (cm
2
)
350
Minimum distance conv. air outlet
to ceiling (mm)
700
Nominal heat output (kW)
4,0
Efficiency (%)
82
CO @ 13% O2 (%)
0,07
Flue gas temperature (°C)
262
Draft (Pa)
>12
Fuel recommended:
Wood logs
Fuel length recommended (cm)
25-30
Fuel charge (kg)
0,78
Refueling interval (minutes)
45
Opening of the air vent
control (%)
50
Operation*
Intermittent*
*Intermitent combustion refers to normal use of a fireplace,
i.e. new wood is inserted when the previous load has burned
down to ember
Warning: If the requirements for ventilation are
NOT complied with, the cooling airflow around the
product will be considerably reduced and
the product can overheat.
This can cause a fire.
3. Safety distances
Firewall
Ensure that the minimum safety distances are fullfiled
(
FIG 1
).
When connecting a steel chimney to the top outlet use
the security distances required by the manufacturer.
Important! When placing the insert on
a combustible floor, a steel plate of at least
0.7mm must cover the entire floor surface inside
the surround. Any flooring made of combustible
material, such as linoleum, carpets etc. must be
removed from underneath the steel plate.
4. Assembly
FIG 4 - to FIG 7
The following tools are necessary:
•
4 mm/ 5 mm Allen key
•
10/13/17 mm wrench
Releasing the stove from the pallet:
The stove is fixed to the pallet with transport locks
arround feet of the insert legs, use a 10mm wrench to
remove locks.
Operating control
When the stove is in an upright position, and prior
to connecting it, control that all functions are easy to
manoeuvre and appear satisfactory.
Door (FIG 3)
Handle is pulled out
Handle is pushed in
Open
Close
Air vent
(FIG 3)
handle to the left
handle to the right
Closed
Open
Adjustment of legs
Open the door under the combustion chamber FIG 4.
Remove the fitting covering the leg adjustment and
adjust the legs with a 13 mm and 17 mm wrench.
Attention! Adjusting the legs affects both the
top and rear connection height.
The insert expands when in use, and for
this reason the surround must NEVER rest
on the insert, but have a gap of about 3 mm.
The insert must neither rest on the bench plate or
against the sides. It is recommended to dry stack
the surround in order to adjust the insert prior
to perforating the chimney for the flue connection.
11
GB
Содержание S-18 F
Страница 18: ...Thermotte FIG 2 Operating control Door opening FIG 3 Montering Assembling D E C B A 18...
Страница 19: ...Adjustment of legs FIG 4 17 mm 13 mm FIG 5 Rear smoke connection 4 mm 4 mm 19...
Страница 20: ...FIG 6 Rear smoke connection FIG 7 Rear smoke connection A B C 5 mm 20...
Страница 21: ...FIG 8 Thermotte assembling FIG 8a 1 2 Front cover assembling 21...
Страница 22: ...FIG 9 Thermotte assembling 3 3 1 1 2 FIG 10 Thermotte assembling 22...
Страница 23: ...FIG 11 Thermotte assembling FIG 12 Thermotte assembling 23...
Страница 24: ...FIG 13 B 4 mm 24 PLASSERING AV SERIENUMMER POSITION OF THE SERIAL NUMBER...
Страница 27: ...4 0 A A B C D E F G 2015 1186 kW ENERGIA ENERGIJA ENERGY ENERGIE A A A A A A Nordpeis AS Nordpeis S18 27...
Страница 28: ...Nordpeis AS Gjellebekkstubben 11 N 3420 LIERSKOGEN Norway www nordpeis no...