6
3.2 ADJUSTMENT OF LEVELING LEGS
The cooker stands on 4 leveling legs. As the leveling legs are adjusted at lower
position, it is required to control whether the product is leveled before operating it.
This adjustment can be made as turning the leveling leg clockwise, if required. It is
possible to raise the product maximum 15mm via the leveling leg. If the leveling legs
are adjusted appropriately, it is required not to move the product by dragging;
otherwise it is required to place it by lifting it up. The leveling leg can be adjusted by
hand or a metal coin with proper size.
3.3 ELECTRIC CONNECTION AND SAFETY
During the electric connection, surely follow the instructions below;
Rated power on
nameplate:
Diameter of supply
cable:
Rated power on
nameplate:
Diameter of supply
cable:
5000W -8700W
at 220V:
3 x 2.5 mm
2
> 8700W at 220 V
3 x 4.0 mm
2
5000W -9100W
at 230V:
3 x 2.5 mm
2
> 9100W at 230 V
3 x 4.0 mm
2
5000W -9500W
at 240V:
3 x 2.5 mm
2
> 8700W at 240 V
3 x 4.0 mm
2
Before proceeding with the electrical connection, verify that the current carrying
capacity of the system and the socket is adequate for the maximum power rating
of the oven.
Electrical installation of the residence and the electrical current plug in use must
be earthed and conform to safety regulations.
A circuit breaker with a contact opening of at least 3 mm must be installed inside
the supply circuit.
Do not use adaptors, multiple sockets and/or extension leads.
Fused switch must be accessible once the oven has been installed.
IMPORTANT: The following diameters of supply cable must be used at least
in case of one phase connection: