The.control.regulator.allows.selection.of.the.speed.of.the.air.in.the.environment.and.the.desired.temperature.in.a.simple.and.intuitive.way..
The.regulator.must.be.positioned.far.from.the.vents.or.from.the.main.heat.source;.if.positioned.in.the.counter-hood.it.must.be.housed.in.a.low.
heat.point..The.simple.installation.is.guaranteed.by.housing.in.classic.recessed.electrical.boxes.fitted.in.common.buildings,.or.wall.mounted.
on.the.outside.of.the.wall.
The.regulator.manages.the.ventilation.with.two.modes.of.functioning.
MANUAL
/
AUTOMATIC
,.to.be.selected.by.pushing.the.relevant.buttons..
OPERATION of the regulator.
The.device.is.switched.on.and.off.by.pushing.the.on/off.button.
1
..
In.the.off.position,.the.light.point.of.the.ON.key.is.lit..In.this.mode.the.system.is.
in.
Stand-by
.mode,.therefore.
always powered by the electric voltage.
By.pushing.the.on/off.button.
1
,.the.status.changes.from.the.
OFF
.state.to.the.
MANUAL
.or.
AUTOMATIC
.operating.state.and.the.respective.LED.lights.up..In.
the.event.of.a.blackout,.the.AUTOMATIC.operating.mode.is.restored!
In.the.event.of.a.
black out
,.the.previously.set.operating.mode.is.restored!
NOTE
:. In. any. of. the. functioning. modes,. if. the.
temperature. of. the. air. coming. out. from. the.
ventilation. outlets. exceeds. the. alarm. limit,. the.
control.unit.increases.the.fans.speed.in.order.to.get.
rid.of.the.exceeding.heat.and.re-establish.the.security.
conditions.of.the.system.
.
if this situation occurs too often, contact the nearest
Service enter
.
Operation in MANUAL.
In.MANUAL.mode.the.fans.always.run.at.the.speed.set.by.the.user,.they.are.NOT.
subject.to.the.temperature.level.set.
Pushing. key.
2
. switches. from. the. fan. SPEED. setting. mode. to. the. desired.
TEMPERATURE.setting.mode.in.the.room.where.the.controller.is.installed,.and.
vice-versa.
The.
Speed
is.set.when.LED.
V
.is.on.(Blue.colour).and.is.increased.with.
key
.
3
..
The.speed.value.can.be.read.from.the.
blue
LED.in.the.scale.to.the.side.
Key.
3
.increases.the.value.to.the.maximum.permitted.then.starts.again.from.the.
minimum.value.
AUTOMATIC operation.
The.AUTOMATIC.mode.is.useful.for.thermostating.the.room.where.the.regulator.
is. installed. as. well. as. ensuring. optimal. comfort. thanks. to. the. automatic.
modulation.of.hot.air.introduced.into.the.environment.by.the.fans.
The.user.sets.the.desired.temperature.in.the.environment.and.the.speed.of.
the.motors;.maintenance.of.these.settings.is.guaranteed.by.the.regulator.that.
automatically.controls.switching.on.and.off.of.the.fans.
Pushing. key.
2
. switches. from. the. fan. SPEED. setting. mode. to. the. desired.
TEMPERATURE.setting.mode.in.the.room.where.the.controller.is.installed,.and.
vice-versa.
The.
Speed
is.set.when.LED.
V
.is.on.(Blue.colour).and.is.increased.with.
key
.
3
..
The.speed.value.can.be.read.from.the.
blue
LED.in.the.scale.to.the.side..Key.
3
.increases.the.value.to.the.maximum.permitted.then.starts.again.from.the.
minimum.value.
The.
Temperature
.is.set.when.the.LED.
C
.is.on.(orange.colour).and.increases.
with.the.
key
.
3
..The.value.of.the.temperature.can.be.read.from.the.
orange
.led.
in.the.scale.to.the.side..Key.
3
.increases.the.value.to.the.maximum.permitted.
then.starts.again.from.the.minimum.value.