INSTALLATION
MAINTENANCE
SERVICE
ASSEMBLY

EFFECTA LAMBDA 35

Rev.EA. 012-05-30

Содержание EFFECTA LAMBDA 35

Страница 1: ...INSTALLATION MAINTENANCE SERVICE ASSEMBLY EFFECTA LAMBDA 35 Rev EA 012 05 30...

Страница 2: ...a user of an ecolabeled product you will contribute to a better environment around you Wood system In order to fulfil the Nordic Ecolabel the accumulator tank volume must be at least 2 000 litres Thi...

Страница 3: ...unction Laddomat 21 60 12 Sleeve placement Accumulator BBS 13 First firing 14 Firing cycle 14 Menus 15 Electrical installation 16 Cleaning and service 17 Cleaning 18 Lever cleaning 19 Adjusting the do...

Страница 4: ...nd serial number Otherwise in the case of a complaint the HVAC industry s current regulations apply Warranty conditions The warranty requires that Installation of the product and the heating system ha...

Страница 5: ...environmental value and thus the best efficiency Normally the preset values do not need to be adjusted for different wood types and humidity levels System description Effecta Lambda has a recommended...

Страница 6: ...The boiler room or boiler house must be equipped with a fresh air intake with the minimum dimensions 150 x 150 5 mm or with a sufficiently large free sectional area to avoid low pressure in the boile...

Страница 7: ...n vessel can normally withstand a pressure of 6 bar Maximum operating temperature is 99 C The volume of a pressure vessel is 10 12 litres depending on the system s overall volume An open vessel must c...

Страница 8: ...ator tank 35 mm pipes are recommended Remember to insulate the pipes between the accumulators to avoid large losses from the system Accumulator tank Effecta Lambda must always work with some sort of h...

Страница 9: ...ould be mixed with the largest at the top of the loading compartment Do not fire with only finely chopped wood or conversely if you heat only using small blocks of wood the boiler may end up at a high...

Страница 10: ...2 Incoming pipe 3 Soot door 3 Wing nut for detaching fan 3 Smoke connection 4 Air intake 4 Splice connector fan 4 Cover plate for soot door 5 Damper motors behind plate 5 Fan 5 Sensor boiler temp 6 H...

Страница 11: ...et tickness firebox Firebox volume Firebox depth Power fan Power Max operating temp Firebox opening Rec tankvolume 600 mm 1260 mm 1280 mm 350 kg 1 5 bar 150x150x630 mm 140 mm 1260 mm 90 liter 500 mm 1...

Страница 12: ...tor tank Boiler water return temp is normally about 70 C At 90 C from the boiler the Laddo mat normally gives 66 C back to the boiler 3 Final phase When the ac cumulator tank is fully charged hot wate...

Страница 13: ...se www effecta se 010 05 22 V50 05 67 E A EXPLANATION 1 SWEEP 1500 X 750 MM 2 1 1 4 70 MM CHARGE 3 1 2 45 MM THERMOMETER 4 1 2 45 MM SENSOR SOLAR 5 1 1 4 70 MM DOCKAGE FLOW RADIATOR 6 2 ELECTRICAL HEA...

Страница 14: ...its own It is therefore not appropriate to stir the in the box during firing If you open the door during firing there is a risk of flashover in the box with poorer function as a result If you burn a l...

Страница 15: ...ust be no fire in the boiler Total operating time for the boiler Displays the operating time after cleaning Press to reset C C A Fired with Running on pellets C No No B Yes Yes C C The pump stops when...

Страница 16: ...t info effecta se www effecta se 011 12 20 50 12 08 E A L1 N Ground CHARGE PUMP OH 95 C POWER 230 V LAMBDA SENSOR BLACK GREY BLUE WHITE RED BROWN BROWN ORANGE YELLOW RED BROWN ORANGE YELLOW RED M M RE...

Страница 17: ...loosen the wing nuts 2 that keep the soot door in place 3 Remove the 7 spirals from the tubes 4 and use the supplied brush to clean the tubes Loading compartment Start by removing the pin 1 located at...

Страница 18: ...gs 2 from dust and soot If the fan is not cleaned the boiler will lose power resulting in slower heating and lower combustion Secondary air In the columns where the flame is drawn down there is a meta...

Страница 19: ...rbulators and clean the tubes with the supplied brush As an extra option you can equip the Lambda 35 with lever cleaning Lever cleaning makes cleaning easier since you do not need to clean the tubes m...

Страница 20: ...pproval of the door locking If the gasket does not seal tightly on the handle side loosen the two bolts 1 that hold the bracket in place Loosen around two turns and slide the latch inwards to tighten...

Страница 21: ...lso loosen the two M12 bolts that hold the locking device in place The new lock is sup plied with boiler the existing is not to be used 3 Remove the two M12 bolts that hold the thermal insulation in p...

Страница 22: ...RADIATOR RETURN BOILER 19 CUTOFF 21 COLD WATER IN 22 CONNECT TO 23 23 CONNECT TO22 24 HOT WATER OUT 25 EXPANSION VESSEL SOLAR 26 SAFETY GROUP SOLAR 27 PUMP SOLAR 28 EXPANSION VESSEL WITH SAFETY VALVE...

Страница 23: ...ol panel Assembly Start by installing the pellets burner in the boiler by first installing the fitting plate 7 with the four wing nuts Then install the swing arm 6 in the fitting plate and outside the...

Страница 24: ...ation in the chimney If flue gas levels are so low that condensation is formed you can remove one or more turbulators in order to increase the flue gas temperature Pellets burning Draft damper A draft...

Страница 25: ...tom right 7 Afterburner chamber The ceramics tray is installed in the loading compartment The purpose of the ceramics is to separate the different combustion zones in the loading compartment It is imp...

Страница 26: ...e that are in the loading compartment They are marked in red in the pictures Centre the lower blocks no 4 and no 5 laterally and fixate them as far forward as possible in the loading compartment Place...

Страница 27: ...effecta se 1 Damper motor 5 Set screw 2 Stop pin 6 Motor shaft 3 Air damper 7 Bracket motor 4 Distance 8 Air box Air damper components To access the damper loosen the four screws holding the cover pla...

Страница 28: ...ructions Increase the pressure The pressure drops in the system There is a leak in the system The wa ter in the vessel has evaporated Wrong first pressure in the pressure vessel Fill up with water and...

Страница 29: ...2 12 2004 Erik Andersson Effecta AB Type plate Modell Model Typ Mod le Milj klass Emission class Emissionsklasse Classe d mission Max drifttryck Max pressure Max Betriebsdruck Pression maximum bar Max...

Страница 30: ...30 Effecta AB V stra R gdalsv gen 21 SE 434 99 Kungsbacka 46 0 300 22320 info effecta se...

Страница 31: ...31 Effecta AB V stra R gdalsv gen 21 434 99 Kungsbacka 46 0 300 22320 info effecta se...

Страница 32: ...32 Effecta AB V stra R gdalsv gen 21 SE 434 99 Kungsbacka 46 0 300 22320 info effecta se...