Nordic AP-L0218 Скачать руководство пользователя страница 5

5

NORDIC

ADDITIONAL SAFETY INSTRUCTIONS  

FOR BATTERIES AND CHARGERS

Use only batteries and chargers applicable for this machine.

4.1 BATTERIES

•  Never attempt to open for any reason.

•  Do not store in locations where the temperature may exceed 40 °C.

•  Charge only at ambient temperatures between 4 °C and 40 °C.

•  When disposing of batteries, follow the instructions given in the section “Protecting the environment”.

•  Do not cause short circuits. If connection is made between the positive (+) and negative (-) terminal directly or via 

accidental contact with metallic objects, the battery is short circuited and an intense current will flow causing heat 
generation which may lead to casing rupture or fire.

•  Do not heat. If batteries are heated to above 100 °C, sealing and insulating separators and other polymer 

components may be damaged resulting in electrolyte leakage and/or internal short circuiting leading to heat 
generation causing rupture or file. Moreover do not dispose of the batteries in fire, explosion and/or intense burning 
may result.

•  Under extreme conditions, battery leakage may occur. When you notice liquid on the battery, proceed as follows:

•  Carefully wipe the liquid off using a cloth. Avoid skin contact.

•  In case of skin or eye contact, follow the instructions below:

1. 

Immediately rinse with water. Neutralize with a mild acid such as lemon juice or vinegar.

2. 

In case of eye contact, rinse abundantly with clean water for at least 10 minutes.

3. 

Consult a physician.

Fire hazard! Avoid short-circuiting the contacts of a detached battery. Do not incinerate the battery.

4.2 CHARGERS

•  Never attempt to charge non-rechargeable batteries.

•  Have defective cords replaced immediately.

•  Do not expose to water.

•  Do not open the charger.

•  Do not probe the charger.

•  The charger is intended for indoor use only.

Содержание AP-L0218

Страница 1: ...OPERATING MANUAL 18V CORDLESS AIR PUMP AP L0218 ...

Страница 2: ...SAFETY Always check that the power supply corresponds to the voltage on the rating plate Power tool plugs must match the outlet Never modify the plug in any way Do not use adapter plugs with earthed power tools Unmodified plugs and matching outlets will reduce the risk of an electric shock Avoid body contact with earthed surfaces such as pipes radiators kitchen ranges and refrigerators There is an...

Страница 3: ... Using such devices can reduce dust related hazards 2 4 POWER TOOL USE AND CARE Do not expect the power tool to do more than it can Use the correct power tool for what you want to do A power tool will achieve better results and be safer if used in the context for which it was designed Do not use the power tool if the switch cannot turn it on and off A power tool with a broken switch is dangerous a...

Страница 4: ...or footing and may become damaged Use the Air Pump only for its intended use Do not alter or modify the unit from the original design or function Always be aware that misuse or improper handling of this Air Pump can cause injury to yourself and others Never leave a Air Pump unattended with the air hose attached to the item being inflated Do not continue to use a Air Pump or hose that leaks air or ...

Страница 5: ...omponents may be damaged resulting in electrolyte leakage and or internal short circuiting leading to heat generation causing rupture or file Moreover do not dispose of the batteries in fire explosion and or intense burning may result Under extreme conditions battery leakage may occur When you notice liquid on the battery proceed as follows Carefully wipe the liquid off using a cloth Avoid skin co...

Страница 6: ...ion Wear safety gloves Wear respiratory protection In accordance with essential requirements of the European directive s Class II The machine is double insulated Earthing wire is therefore not necessary only for charger Ambient temperature 40 C max only for battery Do not expose charger and battery pack to water Use battery and charger only in closed rooms Do not incinerate battery pack or charger...

Страница 7: ...ed during shipping Do not discard the packaging material until you have carefully inspected and satisfactorily operated the product If any parts are damaged or missing please contact your retailer 8 OPERATION APPLICATIONS You may use this compressor for the purpose listed below Inflating tems like motorcycle car and bicycle tires Inflating and deflating low pressure items like air mattresses rafts...

Страница 8: ...main on for up to five minutes To manually shut off press and hold the mode button until the light turns off then release the button INFLATING WITH THE AIR HOSE AND ACCESSORIES The air hose can be used with the provided adaptors to inflate a variety of items Select the appropriate adapter and screw into the valve connector The adapter for sports balls and the adaptor for air mattresses and rafts a...

Страница 9: ...a long period of time with a minimum of maintenance Continuous satisfactory operation depends upon proper machine care and regular cleaning Please charge the battery regularly for example once every 6 months 10 REPAIR Only use accessories and spare parts recommended by the manufacturer If the device is damaged after a few days despite our quality control and your maintenance only an authorized ele...

Страница 10: ...10 NORDIC Fig 1 ...

Страница 11: ...11 NORDIC Picture of the compressors Digital Gauge 1 The unit of blue scale is Bar 2 The unit of black scale is PSI ...

Страница 12: ...12 NORDIC Trigger Digital gauge Storage clips ...

Отзывы: