8
9
User Manual
ENG
User Manual
ENG
Manual drainage
When the air conditioner stops after the water is full,
turn off the air conditioner power and unplug the mains
power plug.
Notes:
Move the air conditioner carefully, so as not to
spill the water in the water pan at the bottom of the AC.
• Place you water container drainage next to side water
outlet behind the body. Unscrew the drainage cover and
unplug the water plug, the water will automatically flow
into the water container.
• During drainage, the body can be tilted slightly
backwards.
• When the water is discharged, use the water plug, and
tighten the drainage cover.
Continuous drainage (only applicable to dehumidifier mode)
1. Unscrew the drainage cover and unplug the
water plug.
2. Set the drainage pipe into the water outlet.
3. Connect the drainage pipe to the bucket.
Cleaning
Before cleaning and maintenance, turn off the air
conditioner and unplug the plug.
• Clean the outer surface of AC with surface of the air
conditioner with a wet soft cloth. Don't use chemical
detergents such as benzene, alcohol, gasoline,… for
cleaning.
• Clean the filter by normal water continuously since it
has direct effect on AC efficiency.
• Unscrew one screw fixed by EVA filter net and back
shell with screwdriver and take out EVA filter net.
• Put the EVA filter screen into warm
water with neutral detergent
(about 40
℃
) and dry it in the shade
after rinsing clean.
Storage
• Unscrew the drainage cover,
unplug the water plug, and discharge the water in the
water pan into other water containers or directly tilt the
body to discharge the water into other containers.
• Turn off the air conditioner, unplug the power plug and
install the water plug and the drainage cover.
• Store the AC and accessories in a dry place
• Remove the batteries of the remote control
Troubleshooting
Do not repair or disassemble the air conditioner by
yourself. Unqualified repair will lead to failure of the
warranty card, and may cause damage to users or
their properties
If problems not listed in the table occur or
recommended solutions do not work, please contact the
authorized service centre.
Technical specification
Power: 220-240 V; 50Hz; 3.95A
Cooling capacity: 7000 Btu/h
Cooling capacity: 2,06 kW
Power consumption: 792 W
EER Grading: 2.6
Warranty
The warranty period is 3 years.
Support
More product information can be found at www.deltaco.se.
Address: SweDeltaco AB Alfreds Nobels Allé 109 146
48 Tullinge Sweden
Email: [email protected] Phone: +46 (0) 8 555 76 200
EC Directive 2012/19/EU
This product is not to be treated as regular household
waste but must be returned to a collection point for
recycling electric and electronic devices. Further
information is available from your municipality, your
municipality’s waste disposal services, or the retailer
where you purchased your product.
The air conditioner does not work.
The cooling ef
fects
is not good
Big Noise
Compressor does not work.
The remote control does not work.
Displays 'E1'
Displays 'E2
There is no electricity
The ambient temperature is too low or high
In cooling mode, the room temperature is lower than the set temperature; i
n
heating mode, the room temperature is higher than the set temperature.
In dehumidification mode, the ambient temperature is lo
w.
The overflow indicator displays "FL".
There is direct sunlight
Doors or windows are open; there are a lot of people; or in cooling mode, there are other sources of heat.
The filter screen is dirty
The air inlet or outlet is blocked
The air conditioner is not placed on a flat surface
Overheat protection starts
The distance between the air conditioner and the remote control is too fa
r.
The remote control is not aligned with the direction of the remote-control receive
r.
Batteries are dead
The room temperature sensor is abnormal.
The pipe temperature sensor is abnormal.
Tu
rn it on after connecting it to a socket with electricit
y.
Recommend using the air conditioner in at the temperature of 7-35
Change the set temperature.
The air conditioner is placed in a room with an ambient temperature of greater than 17
Discharge the water inside.
Move the
A
C away from sunlight
The cooling capacity is not enough
Clean or replace the filter screen
Clear obstructions.
Put the air conditioner on a flat and hard place
W
ait for 3 minutes until the temperature is
lowered, and then restart the air conditione
r.
Let the remote control get close to the air conditioner
, and make sure that the remote
control directly faces to the direction of the remote control.
Replace batteries.
Check the room temperature sensor and related circuitr
y.
Check the pipe temperature sensor and related circuitr
y.
PROBLEM
REASONS