Pos : 135 /Anleit ungen/El ektr onik /FU und St art er/2. M ontage und I nst allation/ Elek trischer Ans chl uss/ SK 1xxE, SK 2xx E, SK 5xxP, SK xxx E-FDS/ Leist ungst eil/ Elektrisc her Ansc hluss Leis tungst eil_T eil0_Übersc hrift [SK 1xx E, SK 2xxE, -FDS, SK 5xx P] @ 19\mod_1511526725283_14638. docx @ 2372465 @ 3 @ 1
2.4.2 Electrical connection of power unit
Pos : 136 /Anleit ungen/El ektr onik /FU und St art er/1. Allgemei nes /Sic herheits- und Ins tall ations hinw eis e und W arn- Gefahrenhinw eise/neu/War n- und Gefahrenhinw eise/ACHTUN G - EMV- St örung der Umgebung [ SK 1xxE, SK 2xx E, 5x xE, 5xxP] @ 32\m od_1553501000447_14638. doc x @ 2519287 @ @ 1
NOTICE
EMC interference to the environment
This device produces high-frequency interference which may make additional suppression measures
necessary in domestic environments (
Section 8.3 "Electromagnetic compatibility (EMC)").
• Use of shielded motor cables is essential in order to comply with the specified radio interference
suppression level.
Pos : 137 /Anleit ungen/El ektr onik /FU und St art er/2. M ontage und I nst allation/ Elek trischer Ans chl uss/ SK 1xxE, SK 2xx E, SK 5xxP, SK xxx E-FDS/ Leist ungst eil/ Elektrisc her Ansc hluss Leis tungst eil_T eil1 [SK 1xx E, SK 2xxE] @ 7\mod_1434530744023_14638. docx @ 226340 @ @ 1
Please note the following when connecting the device:
1 Make sure that the AC power supply provides the correct voltage and is suitable for the current
required (
Section 7 "Technical Data").
2 Make sure that suitable branch circuit protection with the specified rated current range are installed
between the voltage source and the device.
3 Power cable connection: to terminals
L1-L2/N-L3
and
PE
(depending on device)
4 Motor connection: to terminals
U-V-W
Use a 4-core motor cable if the device is being wall-mounted. In addition to
U-V-W
, connect
PE
as
well. In this case, mount the cable shield, if present, on a large area of the metal screw connection
of the cable inlet.
The use of ring cable lugs is recommended for connecting to PE.
Information
Connection cables
Use only copper cables with temperature class 80°C or equivalent for the connection. Higher temperature classes
are permissible.
The maximum connection cross-section can be reduced when using
ferrules
.
Pos : 138 /Anleit ungen/El ektr onik /FU und St art er/2. M ontage und I nst allation/ Elek trischer Ans chl uss/ SK 1xxE, SK 2xx E, SK 5xxP, SK xxx E-FDS/ Leist ungst eil/ Elektrisc her Ansc hluss Leis tungst eil_T eil2 [SK 2xx E] @ 7\m od_1434536283290_14638. docx @ 226437 @ @ 1
Device
Cable Ø [mm²]
AWG
Tightening torque
Size
rigid
flexible
[Nm]
[lb-in]
1 … 3
0.5 … 6
0.5 … 6
20-10
1.2 … 1.5
10.62 … 13.27
4
0.5 … 16
0.5 … 16
20-6
1.2 … 1.5
10.62 … 13.27
Electromechanical brake
1 … 3
0.2 … 2.5
0.2 … 2.5
24-14
0.5 … 0.6
4.42 … 5.31
4
0.2 … 4
0.2 … 2.5
24-12
0.5 … 0.6
4.42 … 5.31
Table 8: Connection data
Pos : 139 /Allgem ein/ Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0. doc x @ 2265496 @ @ 1
Содержание NORDAC FLEX SK 2 E-111-123-A Series
Страница 1: ...BU 0200 en US NORDAC FLEX SK 200E SK 235E Users Manual for Frequency Inverters...
Страница 5: ...Publisher BU 0200 en US 4920 5...
Страница 283: ...Key word index BU 0200 en US 4920 283...
Страница 284: ...6072003 4920...