Industrial gear units – Operating and Assembly Instructions
52
B 1050 en-1819
1 Switching pin protection
2 Mechanical switch
Figure 22: Switching pin with separate mechanical switch
The triggering temperature of the switching pin is usually 120 °C. This ensures that the system is shut
down before the temperature for the melting safety device is reached.
The alignment of the mechanical switch must be checked with the aid of the manufacturer's
documentation prior to commissioning.
The switch must be connected to the evaluation electronics by the operator.
Information
Turbo couplings
As standard, turbo couplings are usually supplied filled with oil.
Pos: 103 /Anleitungen/Getri ebe/3. M ontage, Lagerung, Vorbereitung, Aufstell ung/Antriebskupplung_06-Zahnkuppl ung [B1050, B2050] @ 30\mod_1552982806276_388.docx @ 2511871 @ 4 @ 1
3.22.1.3 Dog coupling
NOTICE!
Gear unit damage
Dog couplings require lubrication with grease to ensure wear-free function:
• Dog couplings must be re-greased according to the manufacturer's documentation prior to commissioning.
Pos: 104 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uch kompakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1
Содержание B 1050 Series
Страница 1: ...B 1050 en Industrial gear units Operating and Assembly Instructions...
Страница 5: ...Publisher B 1050 en 1819 5...
Страница 87: ...7 Appendix B 1050 en 1819 87 Gear units SK 5207 SK 10507 M3 oil screw holes...
Страница 89: ...7 Appendix B 1050 en 1819 89 Gear units SK 5207 SK 10507 M5 oil screw holes...
Страница 93: ...7 Appendix B 1050 en 1819 93 Gear units SK 11207 SK 15507 M3 oil screw holes...
Страница 95: ...7 Appendix B 1050 en 1819 95 Gear units SK 11207 SK 15507 M5 oil screw holes...
Страница 112: ...6052902 1819...