background image

w w w . h a w k e y e e l e c t r o n i c s . c o m  

STEP 3   

Connecting of the Power Cable 

The display has no ON/OFF switch.  Therefore, you will 
need to connect the power harness to a power source that 
will turn the unit on as power is applied.  The key switch or 
an ON/OFF power switch will be suitable for powering the 
unit. 

1.  Connect the BLACK wire in the harness to a negative (-) 

terminal or suitable ground. 

2.  Connect the RED wire in the harness to a positive (+) 12 

Volt switchable power source (key switch, on/off switch, 
terminal block, etc). 

 

N

OTICE

Never use “Twist-On” or “Automotive” type 
connectors. These connectors form a solid electrical 
connection and are less likely to corrode. 

 

STEP 4   

Testing the Display Installation 

Before continuing with your installation, you 
should test the unit to make sure the power wires 
are properly attached. 

1.  Apply power to the unit by turning on the 

power source that you’ve attached the red 
and black wires to. 

2.  The buzzer should beep three times while the display 

illuminates all the LCD graphics for 2 seconds.  “---” 
will then be shown on the LCD.   

If the display operates as per #2 above, continue to the 
“Basic Operation” section. 

If the display does not turn ON: 

1.  Check the power source using a test light or DC volt 

meter.  Make sure there is 12 volt power where the 
power harness connects to both the positive and 
negative sources.  

2.  Check the fuse holder assembly with a test light or DC 

volt meter.  Connect the ground for the test meter or 
light to the vessel’s negative power source. 

Содержание D10DX.06T

Страница 1: ...ring storage NOTES NOTICES AND CAUTIONS WARNING Indicates a potential for property damage personal injury or death IMPORTANT Indicates potential damage to the device and tells you how to avoid it NOTI...

Страница 2: ...department SELECTING THE PROPER TRANSDUCER INSTALLATION The D10DX is available with either a Transom Mount D10DX 01T or a Plastic Thru Hull D10DX 06T Transducer This package includes a plastic Thru Hu...

Страница 3: ...for the transducer and power must reach the mounting location 2 After finding the right location mark a 2 inch hole If your boat has a pre cut hole in the dash panel simply remove the hole plug and p...

Страница 4: ...ise until the bezel locks into place NOTICE Gold and Chrome Alloy Bezels can be purchased on our website to match your factory dash or give your Digital Depth Sounder a custom appearance P N 1000 20 1...

Страница 5: ...likely to corrode STEP 4 Testing the Display Installation Before continuing with your installation you should test the unit to make sure the power wires are properly attached 1 Apply power to the uni...

Страница 6: ...t rely on a visual inspection of the fuse to determine if it is functioning If your depth sounder will not turn on ALWAYS test the fuse with a test light or voltage meter GETTING TO KNOW YOUR DIGITAL...

Страница 7: ...the and indicators illuminate and the icon blinks approximately 3 seconds 2 Release the Keys 3 Press the UP key to access the shallow water alarm setting The icon will illuminate and the indicator wi...

Страница 8: ...lay will return to normal operation after 5 seconds 8 The and indicators will now be illuminated to indicate that a deep water alarm is set When triggered the alarm sounds an audible buzzer for ten se...

Страница 9: ...orner indicating that the depth readings are adjusted to the Keel Offset setting UNITS OF MEASURE The units of measure for the depth readout and alarm functions can be set in 4 easy steps The two sett...

Страница 10: ...CANNOT be constructed of wood Hull thickness LESS than 1 25 32 mm If the answer to any of these characteristics is NO visit our Customer Service Center at www hawkeyeelectronics com to learn about our...

Страница 11: ...y from sources of internal noise as outlined above How Acoustic Noise Effects Performance External sound waves can interfere with the operation of the depth sounder Background noise from sources such...

Страница 12: ...moving downward B On a twin outboard or inboard outboard boat mount between the drives making certain that the transducer is not directly in front of either drive or propeller avoid aligning directly...

Страница 13: ...the transom and look at the bottom of the hull towards the bow Using illustrations A thru I note anything that could interrupt the clean flow of water to the transducer mounting location NEVER MOUNT A...

Страница 14: ...clean the area around the hole inside and outside Make sure to remove all rough spots and petroleum residue STEP 4 Sealing and Installing 1 Remove the nut and rubber gasket from the sensor 2 Apply a...

Страница 15: ...r for extended periods of time all components of the transducer exposed to sea water must be painted with WATER BASED antifouling paint Clear spray on antifouling paints are very easy to apply and can...

Страница 16: ...s or post your own question for our support staff For one on one support please email customerservice norcrossmarine com INFORMATION If you have questions about this device please visit our Customer...

Страница 17: ..._____________ Date of Online Warranty Registration _____________________ Production Date Code ________ 3 digit code located on the device housing LEGAL INFORMATION Made in China Tested to comply with...

Страница 18: ...w w w h a w k e y e e l e c t r o n i c s c o m NOTES...

Отзывы: