Test A, Battery Protection Cut-Out
Before starting this procedure make sure the DC supply voltage to
the refrigerator is correct. The DC supply voltage must be:
■
More than 11.7 VDC to start.
■
Remain between 10.4 VDC to 15.4 VDC to continue operation.
TROUBLESHOOTING
Troubleshoot Compressor Control Module
NOR000950A
SERVICE MANUAL
11
www.norcold.com
Continued on next page.
Is the fuse
intact?
NO
Replace the fuse. Test the refrigerator.
YES
Inspect the fuse on the positive DC
Supply that is connected to control
module terminal “+”.
With the refrigerator turned OFF,
measure voltage at the DC connector.
VDC
10.4 - 15.4?
YES
Repair DC supply voltage.
Test the refrigerator.
NO
With freezer and fresh food
compartments at temperature
setting “5”, measure voltage at DC
connector.
NO
Make sure that the DC supply voltage
is correct.
Remove refrigerator from enclosure,
but do not disconnect the DC supply.
VDC
10.4 - 15.4?
Repair DC supply voltage.
Test the refrigerator.
YES