Introduction

You are now the owner of a Norcold Model DE-541

Dual Electric Refrigerator. When used properly, this
product is designed to give years of trouble free opera-
tion. Please read this manual carefully. It will help you
keep your refrigerator operating efficiently and answer
any questions that may arise concerning your unit.

The refrigeration unit on this model makes use of the

new refrigerant (R-134a) that is 100% CFC Free. This
refrigerant has been developed to provide cooling
which is not linked to global warming and ozone deple-
tion. We, at Norcold, are committed to providing prod-
ucts that are in harmony with the environment.

The model and serial numbers of this refrigerator

must be recorded. You will find these numbers on the
serial tag in the lower right corner when opening the
door. These numbers should be used in any corre-
spondence, either written or verbal, concerning this
refrigerator.

Model: _________________________________

Serial Number: __________________________

If a problem arises with the operation of your refrig-

erator, contact your dealer or an authorized Norcold
Service Center. The service center booklets included
in the information packet list authorized service centers
in the United States and Canada.

Specifications:

 The Norcold Model DE-541 is designed to operate on

the following power sources:

120 volt AC -

132 volt AC max.,

108 volt AC min.

61 hertz max.,

59 hertz min.

12 volt DC -

15.4 volt max.,

12 volt DC min.

Operation on power sources which exceeds the maxi-

mum limits may cause damage to the components of
the refrigerator and void the warranty. Operation on
power sources below the limits will result in poor refrig-
erator performance.

E.S.P.

Extended Cooling Unit Service Protection Plan

An additional two year Service Contract is now

available to original purchasers of Norcold refrig-
erators. For only $25.00 you get:

Two extra years protection against cooling unit
failure

Automatic replacement of defective cooling unit

Pre-paid freight from your dealer to Norcold and
return

Labor free of charge

The E.S.P. (Extended Service Protection) plan

can be obtained by mailing your check for
$25.00*, U.S. funds to:

NORCOLD

P O BOX 4248

SIDNEY OH 45365-4248

If mailing in Canada:

GREG LUND PRODUCTS LTD
P O BOX 760
OAKVILLE ONTARIO CANADA L6J 5C4

E.S.P. is a service contract between Norcold and the

original purchaser. The contract provides replacement

of a defective cooling unit only for this refrigerator
(freight, parts and labor) for an additional period of
two years after expiration of the original Limited War-
ranty. The refrigerator must be delivered to a Norcold
Service Center together with the Norcold E.S.P. card
showing E.S.P. coverage. An E.S.P. card will be mailed
to the original purchaser upon receipt of a completed
Extended Service Protection Plan Application form
and a check covering the E.S.P. charge. E.S.P. cov-
erage is non-transferable and non-refundable.

To register your refrigerator, fill out the Extended

Service Protection Plan Application - i.e.: tear
sheet form in blue envelope or include the following
information (Please Print Clearly):

1. Owner’s name and address
2. Refrigerator model number
3. Refrigerator serial number
4. Date of purchase (Refrigerator or Cooling Unit)
5. Proof of purchase (Refrigerator or Cooling Unit)
6. Check for $25.00* (payable to Norcold)

Applications will be accepted only if they are mailed

within ninety (90) days after date of purchase.

* Ohio residents, add $1.63 sales tax.

DE-541

3

Содержание DE-541

Страница 1: ...the positive 12 volts DC input is grounded in any way cuts in the wire insulation improperly insu lated connections etc a voltage potential could be developed throughout the boat in which corro sion...

Страница 2: ...ct all wiring from physical damage vibration or excessive heat Always disconnect both the AC and DC power sources from the refrigerator when performing routine maintenance All servicing must be perfor...

Страница 3: ...mits will result in poor refrig erator performance E S P Extended Cooling Unit Service Protection Plan An additional two year Service Contract is now available to original purchasers of Norcold refrig...

Страница 4: ...ided at floor level at rear of refrigerator A second opening of at least 50 square inches must be provided directly above the condenser or at either upper side of the refrigerator These openings insur...

Страница 5: ...C power source directly from the battery to the refrigera tor To further limit the possibility of interference and induction due to voltage spikes twist the 12 volt supply wires from the battery to th...

Страница 6: ...tallation of the panel is accomplished by removing the handle assembly in serting the decorative panel and re inserting the han dle assembly see Figure 7 The frame slots are designed to accept panel t...

Страница 7: ...Figure 10 9 Using the 2 phillips screwdriver remove the three screws on the opposite side corresponding to the bottom hinge bracket Relocate the screws in the holes exposed by the removal of the botto...

Страница 8: ...to the refrigerator it defaults to 120 volts AC operation When the refrigerator is disconnected from the shoreline power i e when AC is no longer available the refrig erator switches to DC operation...

Страница 9: ...ecking Door Seal The door seal must seal completely around the entire length of the door This will insure cooling efficiency and prevent frost formation Frequent frost or reduced cool ing are indicati...

Страница 10: ...4 Circuit breaker or fuse may be tripped or blown 5 The AC wall receptacle may be inoperative If refrigerator fails to operate after the above items have been checked contact your dealer or an authori...