Norcold DE-541 Скачать руководство пользователя страница 1

TEK II Dual Electric Refrigerator

Model DE-541Owner’s Manual

CFC FREE PRODUCTS

REFRIGERANT 134A

Contents

Extended Service Protection Plan  .  .  .  .  .  .  . 

3

Ventilation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

4

Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

5

Locating the Refrigerator  .  .  .  .  .  .  .  .  .  .  .  . 

5

Operation and User Instructions  .  .  .  .  .  .  .  . 

8

Refrigeration Care  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

9

Information on Battery Power  .  .  .  .  .  .  .  .  . 

9

Trouble-Shooting  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

10

Wiring Diagram  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  1

1

Limited Warranty  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  1

2

Special Requirements For

Marine Installations:

The DE-541 is internally wired so that the AC and

DC circuits are isolated from each other. If the
positive (+12 volts) DC input is grounded in any
way (cuts in the wire insulation, improperly insu-
lated connections, etc.), a voltage potential could
be developed throughout the boat in which corro-
sion develops on any metal parts exposed to water.

This situation may be avoided by wiring the boat

so that AC and DC grounds are common and wiring
is protected per NNMA CERTIFICATION HAND-
BOOK (1987). Inspect all wiring to insure that
insulation has not been damaged. Plastic wire
clamps are recommended.

To obtain more information on corrosion, a good

reference is:

BOAT AND YACHT CORROSION CONTROL

by Yacht Corrosion Consultants, Inc.

2368 Eastman Ave. #6, Ventura, Ca. 93003

Part No.: 617859C (96-09)

Содержание DE-541

Страница 1: ...the positive 12 volts DC input is grounded in any way cuts in the wire insulation improperly insu lated connections etc a voltage potential could be developed throughout the boat in which corro sion...

Страница 2: ...ct all wiring from physical damage vibration or excessive heat Always disconnect both the AC and DC power sources from the refrigerator when performing routine maintenance All servicing must be perfor...

Страница 3: ...mits will result in poor refrig erator performance E S P Extended Cooling Unit Service Protection Plan An additional two year Service Contract is now available to original purchasers of Norcold refrig...

Страница 4: ...ided at floor level at rear of refrigerator A second opening of at least 50 square inches must be provided directly above the condenser or at either upper side of the refrigerator These openings insur...

Страница 5: ...C power source directly from the battery to the refrigera tor To further limit the possibility of interference and induction due to voltage spikes twist the 12 volt supply wires from the battery to th...

Страница 6: ...tallation of the panel is accomplished by removing the handle assembly in serting the decorative panel and re inserting the han dle assembly see Figure 7 The frame slots are designed to accept panel t...

Страница 7: ...Figure 10 9 Using the 2 phillips screwdriver remove the three screws on the opposite side corresponding to the bottom hinge bracket Relocate the screws in the holes exposed by the removal of the botto...

Страница 8: ...to the refrigerator it defaults to 120 volts AC operation When the refrigerator is disconnected from the shoreline power i e when AC is no longer available the refrig erator switches to DC operation...

Страница 9: ...ecking Door Seal The door seal must seal completely around the entire length of the door This will insure cooling efficiency and prevent frost formation Frequent frost or reduced cool ing are indicati...

Страница 10: ...4 Circuit breaker or fuse may be tripped or blown 5 The AC wall receptacle may be inoperative If refrigerator fails to operate after the above items have been checked contact your dealer or an authori...

Страница 11: ...11...

Страница 12: ...ount of the original consumer purchaser C The Company will not be liable under this Limited Warranty for any of the following 1 Defects which arise by reason of transit damage misuse neglect or accide...

Отзывы: