4. 

Ensure displayed Torque Target is correct. Target will be remembered from the last use.  

 

To quickly alter the target shown press and hold either the up or down arrows                and 
press        to confirm. 
 
To change targets press the        button to exit the run screen and bring up the below menu. 
 

 

 
Then select the targets icon (highlighted above) and press        to confirm.  
 
Use the up and down arrow keys                to highlight required target and press         to 
enter target setup.  
 
Alter the target’s value using the up and down arrows                and confirm by pressing       . 
 
Then press the        button twice to return to the run screen. 
 

5. 

Rotate the handle into a convenient position relative to the reaction bar. Fit the tool onto the 
fastener to be tightened with the reaction bar adjacent to the reaction point. 

 

NOTE: 

The wrench/socket should be engaged to the full depth of the nut/bolt to 
transmit maximum torque and to prevent damage from overloading the 
wrench and damaging the corners of the nut/bolt or socket. 

 

IMPORTANT: 

BE AWARE OF HAND AND FINGER PLACEMENT, 
AVOID ALL OPERATION HAZARDS WHEN 
POSITIONING OR USING EQUIPMENT. 

 

6. 

Adopt a posture to counteract normal or unexpected movement of the tool due to reaction 
forces. 
 

7. 

To run tool press trigger and ‘safe to start’ button simultaneously (as demonstrated 
overleaf)

 to slowly bring reaction bar into contact with the reaction point. The ‘safe to start’ 

button is only required to start the tool, not for continued running. 

 
IMPORTANT: 

BRINGING THE REACTION BAR INTO CONTACT AT SPEED CAN 
LEAD TO INCREASED OPERATOR DANGER, FASTENER DAMAGE, 
REACTION POINT DAMAGE AND TORQUE INACCURACIES, 
ESPECIALLY ON HIGH TORQUE RATE JOINTS. 

 

8. 

Once the reaction bar is safely in place release both the ‘safe to start’ button and trigger and 
wait for half a second. 
 

9. 

Fully press trigger (and ‘safe to start’ button), keep trigger fully pressed until tool stops, then 
release trigger. 

 
10.  Press         to return to the run screen.  