9
proceed to Section 6. (page 12)
5.3
Use a thermometer to measure the current room temperature. Enter
the temperature into the
Room Temperature
text field.
5.4
Move the mouse over the
AutoCal
button and hold the mouse button
down. Continue to hold the mouse button down until the
Signal
Strength
color is green, the temperature displayed matches the room
temperature and the distance displayed is 457. Once all readings are
correct release the
AutoCal
button.
5.5
If the sensor’s temperature reading is not the same as the room
temperature (within ±2°C), adjust the temperature. This is done by
using the
Up/Down
arrows under the
Temperature
display field.
NOTE: If the temperature is not reading the sensor might be
usable, but its accuracy and reliability will decrease. It is
recommended to eventually have the sensor repaired or
replaced.
NOTE: The temperature should not be calibrated until the sensor
has been in the room for a minimum of 15 minutes.
Table 2: Temperature Adjustment Results
Test Result
Action
Temperature is within
±2°C of room
temperature
Continue to the next step.
Temperature is more than
±2°C different than room
temperature.
Try adjusting the temperature setting more.
If it will not adjust to be within the range,
the thermistor may be damaged and will
eventually need replacing.
Temperature cannot be
adjusted to be within ±2°C
of room temperature
The sensor’s thermistor is damaged.
The sensor should still function, but its
accuracy and reliability will decrease. The
sensor should eventually be returned to
NORAC for repair.
The temperature
measurement will not
display.
Cycle the sensor’s power OFF then ON and
try reconnecting the software.
If the sensor’s serial number is displayed
correctly, but the temperature will not
display, the sensor may be damaged.
Содержание UC3
Страница 1: ...Procedure for Testing UC4 UC4 and UC3 Sensors ...
Страница 23: ...20 Date Serial Number Temperature Analog Gain Percentage Signal Strength Distance ...
Страница 24: ...21 Date Serial Number Temperature Analog Gain Percentage Signal Strength Distance ...
Страница 25: ...22 Date Serial Number Temperature Analog Gain Percentage Signal Strength Distance ...
Страница 28: ...25 Notes ...
Страница 29: ...26 Notes ...
Страница 30: ...27 Notes ...