background image

 

 
 
 

15

9.3 

ITEM C20: 43240-28 – CABLE UC5 INTERFACE CAN BUS 

(PIGTAIL) 

 

 

Содержание U5

Страница 1: ...Kverneland Fixed Geometry Installation Manual RA02 ...

Страница 2: ...s International Inc reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously Every effort has been made to ensure the accuracy of the information contained in this manual The technical information in this manual was reviewed at the time of approval for publication ...

Страница 3: ...Introduction 1 2 Technical Specifications 2 3 General UC5 System Layout 3 4 Kit Parts 4 5 Pre Install Checklist 6 6 Ultrasonic Sensor Installation 9 7 Module Installation 12 8 Software Setup 13 9 Cable Drawings 14 ...

Страница 4: ...ing to install the system A thorough understanding of this manual will ensure that you receive the maximum benefit from the system Your input can help make us better If you find issues or have suggestions regarding the parts list or the installation procedure please don t hesitate to contact us Every effort has been made to ensure the accuracy of the information contained in this manual All parts ...

Страница 5: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense This Class A digital apparatus...

Страница 6: ...3 3 General UC5 System Layout Figure 1 illustrates the general layout of the UC5 system components Figure 1 General UC5 System Layout ...

Страница 7: ...ended on any NORAC electrical connections To ensure all stainless steel hardware does not gall or seize apply a light coating of the supplied Permatex Anti seize grease to all threaded parts upon installation Permatex Anti seize lubricant is preferred but other similar anti seize products may be used ...

Страница 8: ...UC5 NETWORK 18 AWG 25M BOOMS OVER 36M C20 43240 28 CABLE UC5 INTERFACE CAN BUS PIGTAIL 1 C30 43250 11 CABLE UC5 BATTERY PIGTAIL 1 E01 43710 UC5 CONTROLLER MODULE 1 E05 43750 UC5 ULTRASONIC SENSOR 2 E10 43760 UC5 NETWORK COUPLER 3 WAY 1 E20 43764T UC5 NETWORK COUPLER 2 WAY WITH TERMINATOR 2 M01 UC5 BC MANUAL VT MANUAL UC5 OPERATORS VIRTUAL TERMINAL 1 M02 UC5 BC RA02 INST MANUAL INSTALLATION UC5 KVE...

Страница 9: ...m hilly mode Insert the boom pin to constrain the long pendulum suspension as shown in Figure 3 Figure 3 Pin Location for Hilly Mode 3 Set the boom suspension to be critically damped Figure 4 Adjust the boom springs and dampers accordingly A Unlock the boom and push boom tip down approximately 75 cm 30 inches B Hold the boom steady for a moment and release C Ensure the boom returns to its relaxed ...

Страница 10: ...t unobstructed area i e no power lines etc 6 Ensure all boom fold operations are functional place a check mark in boxes in Figure 6 7 Bring engine to field operational RPM and record below 8 Record the time seconds it takes for a full stroke for all boom functions To ensure repeatable measurements take the average of 3 trials 9 Not all sprayers will have the functions listed below in Figure 6 Ensu...

Страница 11: ...8 Figure 6 Pre Install Boom Speeds ...

Страница 12: ... the smallest serial number on the left hand side and proceed to the largest serial number on the right hand side Each UC5 sensor has a serial number stamped on the sensor housing Apply a light coating of the supplied Permatex Anti seize grease to all threaded parts upon installation Figure 7 Sensor Serial Number Arrangement ...

Страница 13: ...re from the ground A 2 The centerline of the acoustic cone should be approximately vertical at normal operating heights A 3 The bottom of the sensor must be at least 9 inches in front of the spray nozzles and boom structure B This does not apply for the main lift sensor 4 The bottom of the sensor must be at least 9 inches above the spray nozzles C 5 Ensure there are no other obstructions with a 12...

Страница 14: ...e wing sensor brackets will be near just inside the breakaway sections Figure 9 Wing Sensor Installation A problem can arise if a sensor is not mounted correctly It is possible for the sensor to read off of the boom instead of the ground This may only become apparent once the control system is switched from soil to crop mode ...

Страница 15: ...ble C20 to the control module Cable C20 must be connected to the end of the control module with only one Deutsch connector The free hanging ends of C20 are connected to the sprayer CANbus as labeled on the wires 4 Connect the power cable to 12V and ground and then connect the other end to one of the two CANbus connectors on the end of the control module 5 Route cable C01 from the other CANbus conn...

Страница 16: ...nctions do not work review this manual to check for proper installation 3 Turn on the power for the display terminal using the switch on the side 4 The procedure for the installation of the UC5 Spray Height Control system is now complete Begin the AUTOMATIC SYSTEM SETUP procedure as described in the UC5 Spray Height Control Operator s Manual 5 For optimal performance of the UC5 system there should...

Страница 17: ...ngs 9 1 ITEM C01 43210 05 CABLE UC5 NETWORK 18 AWG 5M 43210 10 CABLE UC5 NETWORK 18 AWG 10M 9 2 ITEM C05 43210 15 CABLE UC5 NETWORK 18 AWG 15M 43210 20 CABLE UC5 NETWORK 18 AWG 20M 43210 25 CABLE UC5 NETWORK 18 AWG 25M ...

Страница 18: ...15 9 3 ITEM C20 43240 28 CABLE UC5 INTERFACE CAN BUS PIGTAIL ...

Страница 19: ...16 9 4 ITEM C30 43250 11 CABLE UC5 BATTERY PIGTAIL ...

Страница 20: ... 3702 Kinnear Place Saskatoon SK S7P 0A6 United States NORAC Inc Phone 1 952 224 4142 Toll Free 1 866 306 6722 Shipping Address 6667 West Old Shakopee Road Suite 111 Bloomington MN 55438 Europe NORAC Europe Phone 33 0 4 26 47 04 42 Shipping Address Rue de l hermitage 01090 GUEREINS France www norac ca ...