background image

 

 
 
 

5

3.2

 

Installation with Control Module Serial Number 3199 and Lower 

1.

 

For this type of installation the power jumper (E21) will need to be installed. 

2.

 

Connect the cable from the ECHO display (D01) to one of the couplers (E20) and connect 

one of the network cables (C01) to the other side of the coupler.  Connect the remaining 
coupler (E20) between the two network cables (C01).   

3.

 

Connect the free end of the second network cable (C01) to the Display Bus connector on 
the control module (E01).  This is the end of the control module that only has one Deutsch 
connector. 

4.

 

Disconnect the network cable from the control module NORAC bus (end of control 
module with two Deutsch connectors).   

5.

 

Connect the 3-way coupler (E10) to the disconnected network cable.  Connect cable C02 
between the 3-way coupler and the control module. 

6.

 

Insert the power jumper (E21) into the remaining connector on the 3-way coupler. 

 

Figure 2: Power Jumper Installation 

Only parts shown in black are included in this kit.  Parts shown in blue are existing 
parts. 

 
 
 

Содержание ECHO-DT1L-INST

Страница 1: ...ECHO Display Kit Loaner Installation Manual ECHO DT1L ...

Страница 2: ...International Inc reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously Every effort has been made to ensure the accuracy of the information contained in this manual The technical information in this manual was reviewed at the time of approval for publication ...

Страница 3: ...3 INSTALLATION 4 3 1 Installation with Control Module Serial Number 3200 and Lower 4 3 2 Installation with Control Module Serial Number 3199 and Lower 5 4 CABLE DRAWINGS 6 4 1 ITEM C01 43220 01 CABLE UC5 NETWORK 14 AWG 1M 6 4 2 ITEM C01 43220 0 5 CABLE UC5 NETWORK 14 AWG 0 5M 6 ...

Страница 4: ...help make us better If you find issues or have suggestions regarding the parts list or the installation procedure please don t hesitate to contact us 1 1 List of Parts Item Part Number Name Quantity C01 43220 01 CABLE UC5 NETWORK 14 AWG 1M 2 C02 43220 0 5 CABLE UC5 NETWORK 14 AWG 0 5M 1 D01 43700 UC5 ECHO DISPLAY PANEL 1 E10 43760 UC5 NETWORK COUPLER 3 WAY 1 E20 43764T UC5 NETWORK COUPLER 2 WAY WI...

Страница 5: ...quipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense This Class A digital apparatus ...

Страница 6: ...number 3 1 Installation with Control Module Serial Number 3200 and Lower 1 Connect the cable from the ECHO display D01 to one of the couplers E20 and connect one of the network cables C01 to the other side of the coupler Connect the remaining coupler E20 between the two network cables C01 2 Connect the free end of the second network cable C01 to the Display Bus connector on the control module E01 ...

Страница 7: ...d network cable C01 to the Display Bus connector on the control module E01 This is the end of the control module that only has one Deutsch connector 4 Disconnect the network cable from the control module NORAC bus end of control module with two Deutsch connectors 5 Connect the 3 way coupler E10 to the disconnected network cable Connect cable C02 between the 3 way coupler and the control module 6 I...

Страница 8: ...6 4 Cable Drawings 4 1 ITEM C01 43220 01 CABLE UC5 NETWORK 14 AWG 1M 4 2 ITEM C01 43220 0 5 CABLE UC5 NETWORK 14 AWG 0 5M ...

Страница 9: ... 3702 Kinnear Place Saskatoon SK S7P 0A6 United States NORAC Inc Phone 1 952 224 4142 Toll Free 1 866 306 6722 Shipping Address 6667 West Old Shakopee Road Suite 111 Bloomington MN 55438 Europe NORAC Europe Phone 33 0 4 26 47 04 42 Shipping Address Rue de l hermitage 01090 GUEREINS France www norac ca ...

Отзывы: