background image

 

 

9

5  

ELECTRICAL INSTALLATION 

 

Figure 6 – Cable Connections 

  Cable C16 and C17 are the only 

cables included in the kit.

 

1.

 

Locate the end of the previously 
installed valve extension cable.  This is 
at the rear of the sprayer. 

2.

 

Disconnect the Case Interface Cable 
from the Valve Extension Cable and 
connect the 6-pin connectors on cable 

C17

 between the cables.   

3.

 

Connect the three pin shroud labeled 
“Connect to C11” on cable 

C17

 to the 

free three pin tower on the valve 

extension cable. 

4.

 

Connect cable 

C16

 to the three pin 

shroud on cable 

C17

5.

 

Connect the 2-pin connector on cable 

C16

 marked 

ROLL CCW

 to the coil 

on the port side of the valve block. 

  The port side is the side of the 

valve block with the left and 
right tilt hoses.

 

6.

 

Connect the 2-pin connector on cable 

C16

 marked 

ROLL CCW

 to the 

other free coil. 

  The pigtails on cable C16 are 

not used for this installation.  

 

7.

 

Tie up all cabling so that it will not 
interfere with any components on the 
sprayer. 

Содержание Case 44 Series

Страница 1: ...Case 44 Series Main Lift Option Installation Manual 4 bolt Spray Height Controller Improving the competitiveness of Industry and Agriculture through Precision Measurement ...

Страница 2: ...ystems International Inc reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously Every effort has been made to ensure the accuracy of the information contained in this manual The technical information in this manual was reviewed at the time of approval for publication ...

Страница 3: ... INSTALLATION 6 4 MAIN LIFT VALVE INSTALLATION 8 5 ELECTRICAL INSTALLATION 9 6 COMPLETING THE INSTALLATION 10 7 ELECTRICAL REFERENCE CABLE DRAWINGS 11 7 1 ITEM C16 44658 46D CABLE VALVE DT ROLL WITH PIGTAIL DT 11 7 2 ITEM C17 44658 62 CABLE VALVE CS4 INTERFACE 12 ...

Страница 4: ...suggestions regarding the parts list or the installation procedure please don t hesitate to contact us NOTICE Every effort has been made to ensure the accuracy of the information contained in this manual All parts supplied are selected specially to fit the sprayer to facilitate a complete installation However NORAC cannot guarantee all parts fit as intended due to the variations of the sprayer by ...

Страница 5: ...with your installation Table 1 Case 44 Series Main Lift System Parts Item Part Number Name Quantity C16 44658 46D CABLE VALVE DT ROLL WITH PIGTAIL 1 C17 44658 62 CABLE VALVE CS4 INTERFACE 1 H01 44865 48 HYDRAULICS FITTING KIT CS4 1 H02 44863 38 HOSE ASSEMBLY 122R2 06 156 IN L 6FORX 6FORX90 2 M01 UC4 CS4 4B INST MANUAL INSTALLATION UC4 CASE 44 SERIES MAIN LIFT KIT 44962D 1 V01 44962D VALVE ASSEMBLY...

Страница 6: ...E SWIVEL TYPE GENDER SIZE TYPE B ORB J JIC OR FLAT FACE P PIPE Fitting Name Example The use of dielectric grease is not recommended on any NORAC electrical connections To ensure all stainless steel hardware does not gall or seize apply a light coating of the supplied Permatex Anti seize grease to all threaded parts upon installation Permatex Anti seize lubricant is preferred but other similar anti...

Страница 7: ...5 Figure 1 Hydraulic Components ...

Страница 8: ...ire the main lift valve to be changed See Section 4 for instructions on how to do this 1 Use Figure 1 as a reference for installing the hydraulics 2 Install the 6MB 6MOR fitting F04 into the A and B ports of the expansion block Figure 2 Figure 2 Expansion Block Assembly 3 Remove the four 4MBP plugs from the 2 station valve block 4 Coat the four o rings in hydraulic oil and install them into the ex...

Страница 9: ...o the tee fitting F03 11 Reconnect the hose that runs from the Case main lift valve block to the main lift tee This connects onto the tee fitting F03 12 Disconnect the lower hose that runs from the Case valve block to the main lift tee 13 Connect the NORAC hose H02 that is connected to the A port on the NORAC expansion block to the tee fitting F03 14 Reconnect the hose that runs from the Case main...

Страница 10: ...7558232 1 Lower the main lift all the way to the bottom 2 Turn OFF the sprayer ignition 3 Loosen the hoses on each side of one of the main lift cylinders located at the back of the sprayer This is to remove any pressure from the system 4 Remove the coils from the main lift valve located under the sprayer 5 Thread the valve out of the valve housing and thread the new valve in 6 Reinstall the coils ...

Страница 11: ... shroud labeled Connect to C11 on cable C17 to the free three pin tower on the valve extension cable 4 Connect cable C16 to the three pin shroud on cable C17 5 Connect the 2 pin connector on cable C16 marked ROLL CCW to the coil on the port side of the valve block The port side is the side of the valve block with the left and right tilt hoses 6 Connect the 2 pin connector on cable C16 marked ROLL ...

Страница 12: ...STALLATION You can now continue to install the remainder of your UC4 Spray Height Control System If the system is fully installed then refer to the UC4 Operators Manual to run an Automatic Install with the CS4 type selected ...

Страница 13: ...11 7 ELECTRICAL REFERENCE CABLE DRAWINGS 7 1 ITEM C16 44658 46D CABLE VALVE DT ROLL WITH PIGTAIL DT ...

Страница 14: ...12 7 2 ITEM C17 44658 62 CABLE VALVE CS4 INTERFACE ...

Страница 15: ...S 3702 Kinnear Place Saskatoon SK S7P 0A6 United States NORAC Inc CALL TOLL FREE 1 866 306 6722 952 224 4142 SHIPPING ADDRESS 6667 West Old Shakopee Road Suite 111 Bloomington MN 55438 Europe NORAC Europe sarl 33 0 4 26 47 04 42 SHIPPING ADDRESS Rue de l hermitage 01090 Guereins France www norac ca ...

Отзывы: