4
4
Visit our Web Site
www.n-c.com
I
NTELLISYS
S
OFT
S
HUT
TM
G
ATE
V
ALVE
M
ODELS
TSS-OP-LiT 08/11
2.0 - Device Specification - General
The following figures and tables summarize specifications of the TSS-series product.
TABLE 2.1 –GENERAL EQUIPMENT SPECIFICATIONS
FEATURE
SPECIFICATION
Dimensions
Refer to
Figures 2.1
and
2.2
, as well as
Tables 2.3
and
2.4
Weight, in lbs (kg)
Refer to
Tables 2.3
and
2.4
Rated input
2A, 2.25
Ω
(only to be operated by Nor-Cal Products’ controller models)
Actuation Speed
2 sec open to closed for 2.5” – 6” valves 4 sec open to closed for 8” and 10” valves
Position Resolution
1:6,144,000 steps for 2.5” – 6” valves. 1:12,288,000 steps for 8” and 10” valves.
Leak Rate
1x10
-9
atm
•
scc/sec He (for valves with Viton® seals)
Allowable Gate Differential Pressure
15 psi (103.4 kPa)
Heating Capabilities
Body can be heated up to 305ºF (150ºC) with optional heater kits.
Protection Class
i
Degree of Protection (iP)
X0
Laser Class
1 (LED’s)
Certifications
CE Standard for Process Equipment including EMC Directive 89/336/EC and Machinery Directive 89/392/EEC
Maximum Altitude
6562 ft (2000 m)
Allowable Ambient Operating Temperature
32ºF – 122ºF (0ºC - 50ºC)
Allowable Ambient Humidity
0 – 95% non-condensing
TABLE 2.2 – TSS RELIABILITY
SPECIFICATION
COMMENTS
*
MTBF
> 2 million cycles or > 11,500 hours
Processes with large amounts of effluent contamination or highly aggressive chemistries may reduce the MTBF
due to condensation on moving parts and/or O-ring degradation.
*
Warranty
1 year
installation Clearance
For iQ-series TSSs 3” (75 mm) is required on all perforated sides. Otherwise, a minimum of 3 ½” (90 mm) is
needed on top to allow for connector(s).
Downloaded from
Arrow.com.
Downloaded from
Arrow.com.
Downloaded from
Arrow.com.
Downloaded from
Arrow.com.