Section 4: Preparing for Use (cont.)
•
Attach the calibration cup to
the spray head, ensuring correct
orientation.
•
Squeeze the trigger until the
herbicide is visible in the flow
window (approx 20 seconds).
Release the trigger to stop the
flow once the herbicide window
is full.
•
Once primed, invert the lance,
squeeze the trigger and allow
the fluid to empty from the
calibration cup.
•
When the calibration cup is
empty, release the trigger.
Calibrating
Please Note:
For full calibration
information, always refer to the
instructions on the product label.
•
With the calibration cup attached,
set the flow rate control to the
required gauge setting (A-G).
•
Point the lance downwards.
•
Squeeze the trigger.
•
Time the flow into the calibration
cup for 30 seconds, or as per
product label instructions.
Release the trigger to stop
the flow.
•
Take a reading of the herbicide
level on the calibration cup.
•
If there is too little fluid, turn the
flow rate control anti-clockwise
to increase the amount. If there is
too much fluid, turn the flow rate
control clockwise to reduce the
amount.
•
Return the fluid by inverting the
lance and squeezing the trigger.