When you select BAR GRAPH from the main menu and choose EDIT, you will be
able to modify the following settings:
Sample Rate – 512, 1024, 2048, 4096, 8192. Faster sample rates are more
accurate at higher frequencies, but will create larger files.
Bit accuracy – 16, 14, 12, 10 bit. Higher bit accuracy results in higher data
accuracy, but will create larger files.
Recalibrate on temp change – Adjusts A/D Midpoint after 10 degree change if
needed.
Company
–
User setting for record
Seis. Location
–
User setting for record
Notes – User setting for record
Distance to source – None, 1-99999 ft (User setting for record)
Operator – User setting for record
Sensitivity
–
Low or High. Changes dynamic range. High sensitivity trades range
for increased resolution. Numbers depend on sensor type.
Monitor Bargraph
–
Both, Seismic, Air. Chooses which sensor(s) to monitor.