TEST AND ADJUSTMENT
❒
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
1
/
2
minute warm up period
before it will detect motion. When first turned
on, wait 1
1
/
2
minutes.
❒
Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.
Motion
Motion
The detector is most sensitive to motion across its field
of view.
❒
Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒
Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area.
Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
❒
Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 150°
Electrical Load . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
Operating temperature
range . . . . . . . . . . . . . -22 to 120°F (-30 to 49°C)
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features
in products previously sold.
NOTE: Sensor has a 1
1
/
2
minute warm up period
before it will detect motion. When first turned
on, wait 1
1
/
2
minutes.
RANGE
10 5 1 TEST
ON-TIME
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where
pets or traffic may trigger the control.
•
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
70 ft.
(21 m)
8 ft.
(2.4 m)
150°
MIN
MAX
Least Sensitive
Most Sensitive
Sensor
WARNING: Risk of fire. Do not aim the lamps
at a combustible surface within 3 ft. (1 m).
Maximum Range
Maximum
Coverage Angle
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage