background image

WARNING!!! IT IS NECESSARY

TO EXECUTE THE MEMORY´S RESET!!!

RESET PROCEDURE

This operation cancels all codes in the memory. It is necessary to execute the memory´s reset before learning the fi rst TX, 

so that the previously codes and the code that are not used, are not in the memory:

1. 

Make sure that the output are deactivated

 (The green led L1 and L2 

are turned off 

).

2. 

Make sure that the receiver is not learning. The red led L3 must be switched off .

3.  Keep pressed the button P1 till the red led it is switched on. (10 seconds) and then release it.

4. 

Wait that the red led will be switched off  or fl ashing.

LEARNING OF A TRANSMITTER

1. 

Make sure the exit´s receivers are not in use and not in learning the green led (L1 and L2) are turned off .

2. 

Push and release the push-botton corresponding to the exit of the remote control, P1: OUT1 or P2: OUT2

3. The green led associated will lit on

4. 

Press the transmitter’s button within 5 seconds. If the code has been learnt, the red led fl ashes fast for 2 seconds. If the red 

led fl ashes slowly it means that the memory is full. If the red led doesn’t fl ash it means that the transmitter is not compatible. 

In order to learn other codes on the exit 1 repeat operation 1.

TRANSMITTER’S CANCELLATION

(not fot EB rolling).

This function can cancel only one single remote control:

1. 

Press and keep pressed the buttons P1 and P2

2. 

Press the button of the remote control which code need to be cancelled

3. Led L1 and L3 fl ash briefl y to confi rm the cancellation of the code

4. 

Release all buttons 

DEACTIVATION OR ACTIVATE OF ONE REMOTE CONTROL

 (for Eb rolling).

The deactivation of one single remote control is useful in case the automatic memorization is always activate (DIP6 ON) and 

it doesn’t need to be memorized when the signal will be received. This procedure is useful in case to invert the managing of 

the remote control, if It was activated or deactivated, and if it was deactivated, it will be activated:

1. 

Press for 2 seconds and then release the buttons P1 and P2 on the control board

2. 

Press the button of the remote control.

3. If the code is activated it will be deactivated and vice versa.

4. 

If the buttons P1 and P2 will be pressed for more than 5 seconds, the code will be cancelled from the memory of the 

receiver 

  

CODE’S MEMORIZATION

  RESET PROCEDURE

FUNCTION STEP BY STEP

The receiver´s exit can be made also used for the operation step by step. To active or disactive the operation it is suffi  cient 

to push the button when only the relative exit is active (green led switched on, L1: OUT1 and L2: OUT2). If the exit was in 

normal, the operation step by step will be operating, while if the following operation was already active, the exit will return 

to the normal function.

FUNCTION STEP-BY-STEP WITH TIMING. 

The output works as the step-by-step mode (DIP 7 OFF) with a self-deactivation after a planned time. To activate this function 

the receiver must be in normal function (not step-by-step or step-by-step with timing) so when the output has been activated:

1. 

Press the button in the receiver corresponding to the output until the led start fl ashing and then release the button.

 

2. 

The green led fl ashes, L1: OUT1 or L2 OUT2.

3. Let the time goes for maximum 512 seconds for the timing and then press the button again.

4. 

To deactivate the function step-by-step with timing, it is suffi  cient to press the button in the receiver to the corresponding 

output when the output is activated.