4 Channel receiver with self-learning,

it manages standard codes from 12 till 80

and rolling HCS© or rolling EB

RX2-LUCI

+ 12/24 Vac/dc

1

2

3

4

- 12/24 Vac/dc, - Antenna

BUS

P1

+ Antenna

P2

L1

L2

L3

5

6

7
8

9

10

N.O.

COM

OUTPUT 1

N.C.

N.O.

COM

OUTPUT 2

N.C.

POWER SUPPLY (1 and 2). 

The receiver can be powered from 12 to 24 volt in AC and DC as well. The polarity must be 

used in case of DC (positive on clip nr. 1). 

ANTENNA (2 and 4). 

The antenna must be connected with positive (the spirit) on the contact no.4 and negative (stocking). 

If only one is used (17cm for freq. 433,92 Mhz), this has to be connected to contact n°4.

OUTPUT (from 5 to 10).

 The normally opened rele´ of exit 1 is on contact n° 5 and 6 while the normally closed contact is 

on contact n° 5 and 7. For output 2 the normally opened contact is present on clips n° 8 and 9 while the normally closed 

contact is on contact n° 8 and 10. 

It is recommended not to connect such contacts to high tension and to make sure that the 

current not exceed 5 ampere.

  CONNECTION OF THE RECEIVER

DIP 1 ON -> 12V

DIP 1 OFF -> 24V

  PROGRAMM DIP

DIP 1

Power supply setting: 

OFF if connected to a 24V power source - ON if connected to a 12V power source.

DIP 2

ON

EB Rolling

 code function activated

DIP 3

ON

HCS rolling

 code function activated

DIP 4

ON

Reduce the output activation from 0.8 to 0.3 s

DIP 5

ON

The receiver will accept only the same type of code of the fi rst memorized remote controls, the next 

one should have the same type of code.

DIP 6

ON

If you are using the HCS rolling code function, DIP 3 in ON, keep pressed button 1 and 2 of the remote 

control which has been already memorized, the codes learning is in the OUT1. If you are  memorizing 

EB rolling code, DIP 2 ON, you activate the self-memorization of the remote controls with the same 

installation code.

DIP 7

ON

Excluding the step-by-step function on the time outputs.

DIP 8

ON

It activate the managing of the inverted code (diff erential Manchester encoding) 