![Nokia RH-29 Series Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/nokia/rh-29-series/rh-29-series_manual_1699380014.webp)
RH-29
Company Confidential
6b - RF Troubleshooting
Nokia Customer Care
Page 10
Copyright
©
2004 Nokia Corporation
Issue 1 05/2004
Company Confidential
Select
Testing
Alt-S
RF Controls
R
Wait until the RF Controls window pops up
Select
Band
GSM900 or GSM1800
Active unit
RX
Operation mode
Burst
RX/TX Channel
37 or 700
Select
Testing
Alt-S
RSSI reading
G
The setup should now look like this:
Apply a signal with a frequency of
EGSM900: 942.467 MHz (channel 37 + 67.710kHz offset)
GSM1800: 1842.867 MHz (channel 700 +67.710kHz offset)
and a power level of -80dBm to the RF-connector (remember to compensate for cable
attenuation).
In RSSI reading click Start.