Product Code
MJ-17 Module Test Jig:
0770586
Figure 3: View of MJ-17
Note: The nominal supply voltage for MJ-17 is 4.0 V.
Over voltage protection operates at 4.5V.
If overvoltage protection is triggered, the normal jig operation can be restored by
switching OFF the power supply, replacing the fuse (if not OK) and restoring valid
power supply.
MJ-17 includes over voltage, overcurrent and reverse polarity protection.