CCS Technical Documentation
Troubleshooting
RH-13
Issue 1 11/02
ã
Nokia Corporation
Page 21
Power supply for data cable
DLR-3 needs power supply for data transfering. SGND will supply 2.8V to DLR-3.
- Start phone to normal mode when checking DLR-3 detection
Figure 9: Fault tree, data cable.
Sleep Clock
Missing/non-functional sleep clock causes
• Entering sleep mode fails (higher current consumption -> shorter standby time)
• Baseband self tests cannot be run
DLR-3 data cable
doesn't work
Connect DLR-3, check
DLR-3 detection
Change UEM
Check V151,V152,R161,
C164,L158
Check the
components of
XMIC, HEADINT
and MICB2 lines
Check bottom
connector
Check SGND voltage from
bottom connector
(2.40-2.90V)
Ok
Fail
Ok
Fail
Ok
Ok
Ok
Check VFlash2
(~2.8V)
OK
Fail