8 Connect spectrum analyzer probe to the UHF VCO output and record signal level
and frequency. Signal level should be around -5 dBm and frequency 2029.2 MHz.
Figure 22: UHF VCO.
9 Repeat measurement for channels 128 and 251.
Step 3. RX chain checking
1 Set signal generator frequency to 881.46771 MHz and level to -80 dBm.
2 Set phone receiver to continuous mode with full gain using Phoenix.
Figure 23: RF controls
3 Connect oscilloscope probe to one of the RX I/Q test points on PWB (all four
testpoints J808, J809, J818 and J819 are located behind display)
G802
Output