Original 08/98
Flash Programming failure (1)
Flash programming doesn’t work
via panel connector
If the fault information from prommer is:
a) MCU doesn’t boot
b) Serial data line failure
c) Serial clock line failure
connect watchdog disable (WDDIS, J111)
line to the ground
VBB (R115, C107 upper side) 2.8 V
VXO (C149 upper side ) 2.8 V
J227 master reset (Purx) = ”1” (2.8 V)
RfClk (R213 lower side) 13 MHz sine wave
clock signal: 500 mV
pp
min
Check that following lines are correct:
FTX (fbus_tx) line: X001 pin 1 ––> R215
FRX (fbus_rx) line: X001 pin 2 ––> R201
FCLK (MBUS) line: X001 pin 3 ––> R115
Check also pullup and pulldown resistors R115, R201, R215
GND: X001 pin 7 ––> GND
Check C213, R213
RFC (C664) 13 MHz
800 mV min
Check buffer V660 and
VCTCXO G660
See section ”Phone is totally dead”
J228 sleep clock (SCLK)
square wave 32 kHz
Check sleep
clock circuitry
(B101, R154..)
Faulty circuit N100
or overloaded PurX line
Enable the selftest function of D200 by connecting
J229 to ground
Connect oscilloscope to testpoint J225
(ExtSysResetX) and switch power on
Voltage level rises to ”1” after power on at testpoint J225
There could be open pins in circuits D200 (D220, D240)
(open joints may be detectable with microscope)
If not, the PCB or D200 (D220, D240) is faulty.
There is a shortcircuit
somewhere in memory control
lines or MCU address lines or
MCU lower (7:0) data lines