PAMS Technical Documentation
Troubleshooting and Tuning Instructions
NHM-7
,VVXH
1RNLD&RUSRUDWLRQ
3DJH
Audio fault 2
Audio
faults 2
Is microphone working?
Try change bottom
connector X100.
Is it working now ?
Retest
No
Yes
Set phone in LOCAL mode.
Use Phoenix Audio Test.
Set HP IN, EXT OUT, LOOP ON.
No
Measure MICB1
voltage from MICP pads.
Is it ~2.1V ?
Check L105,
C105, C152,
C156, R152,
C168, C166,
C215 and line.
If OK –>
Change UEM
No
Check C151,
R157, C105,
C154 and line.
If OK –>
Change UEM
Yes
Audio
faults 3
Yes