Energy management calibration
During energy management calibration, the A/D converter, BSI, Btemp, Battery voltage, Charg-
er voltage and Charger current are calibrated. For detailed information and instructions see
EM-calibration instructions in the service manual.
Troubleshooting tips
ADC-offset over limits
Inspect the BSI line, connectors (hotbar and board to board connector) and components in it
(Capacitor C226, ASIP R385, Pull-up resistor R220). If these are OK, change UEM.
BSI Gain over limits
Inspect the BSI line, connectors (hotbar and board to board connector) and components in it
(Capacitor C226, ASIP R385, Pull-up resistor R220). If these are OK, change UEM.
Vbatt offset and Gain
Inspect Vbatt lines and components in it.
Vchar over limits
Inspect components that are connected Vchar line: Filtering capacitors C384, C385, TVS
V381, L380 and Fuse F380. If those are OK, change UEM.
Ichar over limits
Inspect components that are connected Vchar line: Filtering capacitors C384, C385, TVS
V381, L380 and Fuse F380. If those are OK, first change the current sense resistor (R190), if
calibration is not still successful change UEM.
Calibration can be checked using ADC-reading. Known voltages, currents and resistances are
fed and read by ADC-reading, read values and known values can be compared.
ADC-reading
Divided and scaled battery voltage, Charger voltage, Charger current and BSI values can be
read by this tool. Read values a few times before you can be sure that results are accurate.