Loopset LPS-3
PAMS Technical Documentation
Page 11
Nokia Mobile Phones Ltd.
Issue 1 12/99
Plug and X100 connector signals
Plug
/
Jack
Pin
in
x100
Name
Function
Min
Typ
Ma
x
Unit
Description
1
1
XMicP
Loopset microphone in
1.6
k
W
Loopset source AC impedance ref 1kHz
Loopset microphone in-
put
(from accessory to
400
m
A
Bias current
(from accessory to
phone)
200
mV-
p–p
Maximum signal level
Loopset detection
(from accessory to
2,4
2.8
6
V
No Loopset (ref. XMicN).
(from accessory to
phone)
1.1
2.2
3
V
Loopset connected (ref. XMicN). Mic bias
ON
Ead /
hookint
mbus
Ext accessory detection
Bias OFF
0
0.3
0.1
1.0
0.3
5
V
Loopset connected (ref. GND).
Ead /
Hookint
mbus
Button closed
DCT3.n
Mic bias ON DCT4
0.7
0
1.0
0.8
0
1.2
V
Loopset connected (ref. GND).
3
2
XMicN
Micr signal
10
nF
Series output capacitance
2
3
XEarN
EAR –Signal
(from phone to acces-
47
W
Output AC impedance ref 1kHz
(from hone to acces
sory)
10
nF
Series output capacitance
150
300
450
W
Load AC impedance ref 1kHz
2.0
Vpp
Max. input level. No load
4
4
XEarP
Ear + signals