Table 10
DC Cable Requirements for 80 W RF Modules
Variant
Total Configured
output power
RET/MHA
Minimum DC
voltage
Power
Cable
2100/1900/18
00
(FRGT/FXFC/
FXEB)
<= 180 W
Any
Any
Single
2100/1900/18
00
(FRGT/FXFC/
FXEB)
> 180 W
Yes
< 46.5
Dual
2100/1900/18
00
(FRGT/FXFC/
FXEB)
> 180 W
Yes
>= 46.5
Single
2100/1900/18
00
(FRGT/FXFC/
FXEB)
> 180 W
No
< 41.5
Dual
2100/1900/18
00
(FRGT/FXFC/
FXEB)
> 180 W
No
>= 41.5
Single
850/900
(FXCB/FXDB)
<= 180 W
Any
Any
Single
850/900
(FXCB/FXDB)
> 180 W
Yes
< 40
Dual
850/900
(FXCB/FXDB)
> 180 W
Yes
< 46.5
Single
850/900
(FXCB/FXDB)
> 180 W
Yes
>= 46.5
Single
850/900
> 180 W
No
< 41.5
Single
8)
Total configured output power is the total power for all three branches. For example, a 2+2+2 @ 40 W is
equal to 240 W.
9)
The following power cables are available: FPCA 472806A (Dual, 2 m, 6.6 ft), FPCB 472817A (Single, 2 m,
6.6 ft), FPCC 472823A (Single, 2 m, 6.6 ft), FPTA 472246A (Single, 4 m, 13.1 ft). The dual power cable
requires two available PWR outputs on the System Module or PDU (excluding PWR AUX). It is
recommended to use the next available connectors in sequence. The FPCC and FPTA require removing
the connector from one end. Consider future expansion when choosing single or dual power cables.
Flexi Multiradio BTS Radio Module and Remote Radio
Head Description
Power requirements and output power
Issue: 05
DN0951745