CU-4
Control unit
CU-4 is a general service tool used with a module jig and/or a flash
adapter. It requires an external 12 V power supply.
The unit has the following features:
•
Software controlled via USB
•
EM calibration function
•
Forwards FBUS/Flashbus traffic to/from terminal
•
Forwards USB traffic to/from terminal
•
Software controlled BSI values
•
Regulated VBATT voltage
•
2 x USB2.0 connector (Hub)
•
FBUS and USB connections supported
When using CU-4, note the special order of connecting cables and
other service equipment:
Instructions
1 Connect a service tool (jig, flash adapter) to CU-4.
2 Connect CU-4 to your PC with a USB cable.
3 Connect supply voltage (12 V)
4 Connect an FBUS cable (if necessary).
5 Start service software.
Note:
Service software enables CU-4 regulators via USB when
it is started.
Reconnecting the power supply requires a service software
restart.
RM-704
Service Tools and Service Concepts
Page 2 – 6
COMPANY CONFIDENTIAL
Issue 1
Copyright © 2011 Nokia. All rights reserved.
Содержание C2-00
Страница 86: ...RM 704 RF Troubleshooting Page 4 10 COMPANY CONFIDENTIAL Issue 1 Copyright 2011 Nokia All rights reserved ...
Страница 91: ...RM 704 RF Troubleshooting Issue 1 COMPANY CONFIDENTIAL Page 4 15 Copyright 2011 Nokia All rights reserved ...
Страница 135: ...5 System Module Nokia Customer Care Issue 1 COMPANY CONFIDENTIAL Page 5 1 Copyright 2011 Nokia All rights reserved ...
Страница 163: ...Glossary Nokia Customer Care Issue 1 COMPANY CONFIDENTIAL Page Glossary 1 Copyright 2011 Nokia All rights reserved ...