![Nokia Alcatel-Lucent OXO Connect Compact Скачать руководство пользователя страница 71](http://html.mh-extra.com/html/nokia/alcatel-lucent-oxo-connect-compact/alcatel-lucent-oxo-connect-compact_installation-manual_255140071.webp)
Fleet reference
Sub-fleet reference
Installation reference
Partner using internal
customer reference
mandatory
optional
Customer reference
Partner not using
internal customer
reference
mandatory
optional
CC-Product-ID
(*)
(*)
: Identifier allocated by eBuy at the license registration.
4.
Configure the network parameters:
Eth0 - IP address
Enter the PBX IP address (mandatory field)
This corresponds to the PBX network interface accessible
from its
Eth0
port
Eth0 - mask
Enter the PBX subnet mask (mandatory field)
Default router address
Enter the router IP address (mandatory field)
VLAN ID
Enter the VLAN identifier (if needed)
DNS
Enter the DNS server IP address (default value: 8.8.8.8)
(mandatory field)
5.
Configure the web proxy address and credentials (if needed)
6.
Click the validate button
This closes the registration page
The PBX sends a First Time Registration (FTR) request, including the following information:
• A partner fleet reference (mandatory)
• A partner sub fleet reference (optional)
• An installation reference (customer reference or CC-Product-ID) (mandatory)
• A CPU-ID (automatically provided by the PBX)
As long as FTR does not succeed, the PBX keeps sending FTR requests. After the PBX is
connected to the Cloud Connect infrastructure, the country target and license keys are pushed to
the PBX. When the operation is complete, the PBX can be viewed in the Fleet Dashboard of the
customer with its CPU-ID.
7.
From the PBX home page, click the
IDs
button and verify that FTR was successful
It is successful when the
CC Product ID
field contains a value.
At this stage, the PBX runs with the appropriate country target and license keys. The PBX can be
configured using a phone set or the OMC.
5.2 Loading manually the country target and license keys via OMC
5.2.1 Before starting
The computer, on which the OMC application is running, must be connected to the LAN port of the
main CPU board. The default IP address for the main CPU board is
192.168.92.246
. The computer
must be configured in static mode with an IP address and subnet mask compatible with those of the
main CPU board (for example:
192.168.92.1
and
255.255.255.0
).
Chapter
5
Loading the country target and license keys
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
71/216