Steps
1. Start Phoenix Service software.
2. Establish connection to the phone.
From the File menu, choose Open Product.
From the list, choose RM-51.
3. From the Testing menu, choose RF Controls.
4. In the RF Controls window:
i
Select Band GSM1900.
ii Set Active unit to Rx.
iii Set Operation mode to Continuous.
iv Set RX/TX channel to 661.
v Set AGC to 12.
The frequency or level of signal generator is 1960.0677MHz, -60dBm.
Note:
Because DC compensation does not work during continuous mode, DC offset level at RXI and
RXQ will gradually shift from the optimized level.
To have the most reliable result, it is highly advisable to set the operation mode from burst to
continuous just before measuring values and complete measurement within no longer than 30
seconds.
RM-51
Nokia Customer Care
RF troubleshooting
Page 7–14
Company Confidential
9238460 (Issue 1)
Copyright ©2005 Nokia. All Rights Reserved.