![Nokia 1606Arte Скачать руководство пользователя страница 94](http://html.mh-extra.com/html/nokia/1606arte/1606arte_service-manual_252250094.webp)
RH-109
System Module Description
Technical specifications Main RF characteristics for CDMA phones
QSC6055 System Module Description
Parameter
Unit
CELL : 810
PCS : 1200
Number of RF channels
AWS : 900
CELL : 30kHZ
PCS : 50kHZ
Channel Spacing
AWS : 50kHZ
Environmental condition
Environmental Condition
Ambient Temperature
Notes
Normal Operation
-15
℃
…+55
℃
Specifications
fulfilled
Reduced Performance
+55
℃
…+70
℃
Operational only for short periods
Intermittent or No
Operation
-40
℃
…-15
℃
and +70
℃
…+85
℃
Operation not guaranteed but an
attempt to operate will not damage
the phone.
No Operation or Storage
<-40
℃
and >+85
℃
No storage. An attempt to operate
may cause permanent damage.
Charging Allowed
-15
℃
…+55
℃
Long Term Storage
Conditions
0
℃
…+85
℃
Humidity and Water
Resistance
Relative humidity range is 5 to 95%.
Condensed or dripping water may
cause intermittent malfunctions.
Protection against dripping water
has to be implemented (enclosure)
mechanics. Continuous dampness
will cause permanent damage to
the module.