background image

2

DESCRIPTION

FTR970 is a radio data receiver for Nokeval MTR series wireless transmitters. It receives and 

buffers the data packets that wireless transmitters have sent. It automatically recognizes the types 

of the transmitters, so different kinds of transmitters can be used simultaneously. Transmitters can 

also have different transmission intervals. FTR970 uses license free 433.92 MHz frequency band 

(ISM) so it can be freely used, for example, almost in whole Europe.

FTR970 is housed in plastic field enclosure that provides good protection against humidity and 

dust.  The receiver is connected to a computer using RS-485 or RS-232 bus and it requires Pro-

moLog  application that reads the information from the device.

Nokeval SCL protocol is used for data transmission between the receiver and the computer. Mul-

tiple receivers can be connected in parallel to an RS-485 bus to increase the coverage area. The 

receiver has three diagnostic LEDs and it requires 8..30 VDC power supply.

Manufacturer

Nokeval Oy 

 

Tel +358 3 3424800

Yrittäjäkatu 12 

  Fax +358 3 3422066

FIN-37100 

  www.nokeval.com

Finland 

  Sales: [email protected]

 

  Technical support: [email protected]

coverage area

50...200 m

FTR970

RS-485 or RS232

PromoLog

Содержание FTR970

Страница 1: ...User manual 13 11 2007 Firmware version 3 1 FTR970 RADIO DATA RECEIVER Nokeval ...

Страница 2: ...closure that provides good protection against humidity and dust The receiver is connected to a computer using RS 485 or RS 232 bus and it requires Pro moLog application that reads the information from the device Nokeval SCL protocol is used for data transmission between the receiver and the computer Mul tiple receivers can be connected in parallel to an RS 485 bus to increase the coverage area The...

Страница 3: ...by using detachable screw post connector terminals 1 and 2 Both supply voltage connec tors are internally connected The receiver is protected against wrong polarity of the supply volta ge The supply voltage s negative terminal is also used as ground for RS 485 and RS 232 Connections 8 30 VDC GND DC jack 1 2 3 4 ...

Страница 4: ...e done via D1 data line by putting the jumper to position Yes Last device on bus should have termination jumper on It makes AC termination for the line which means that there is 1nF capacitance and 110 ohm resistance in series between the lines Maximum length for the bus is 1km and it allows 32 devices more devices can be connected by using repeaters RS 232 When used with RS 232 bus jumper J11 has...

Страница 5: ...5 J11 J7 Jumpers ...

Страница 6: ...600 1200 2400 4800 9600 and 19200 Receive submenu Rcv CRCChk If selected CRC checksum of received data packets is checked and corrupted packets are rejected The setting is on by default and there is no reason to disable the setting CH1ID CH4ID Four MTR series transmitters except MTR260 can be defined to act as certain channel For example when FTR970 receives MEA CH 1 command it sends latest receive...

Страница 7: ...ese commands are explaided in the list below FTR970 supports the following SCL commands TYPE Returns the model name and software version SN Returns the device s serial number for example A123456 MEA CH x Returns the last received value from the device that is defined as channel x DBG 1 Returns the oldest unread data packet from the buffer DBR 1 xx Returns a data packet from the ring buffer location...

Страница 8: ...ss 0 123 RS 232 Connector Detachable screw post connector with 3 81 mm raster terminal 6 TxD terminal 7 RxD Maximum cable length is 15 m Protocol Nokeval SCL Baud Rates 300 600 1200 2400 4800 9600 19200 Power supply Connector 1 1 3 mm DC jack centre positive Connector 2 detachable screw post connector with 3 81 mm raster terminal 1 terminal 2 Voltage 8 30 VDC Current consumption 60 mA Environment ...