16
Equipment
Action
Troubleshooting
Possible cause
User solution
Autoritzet technical service
AIR
Press air massage
push-button with led
Button light OFF, air massage OFF
Diferential switch or magnetothermic off
Connect the differential switch or magnetothermic
-
Button light OFF, air massage ON
Faulty push-button
-
Change the push-button
Button light ON, air massage OFF
Defective blower or connections
-
Check connections and messure the blower input
(230V AC)
Check the noise
Change the blower(if applicable)
Problem with the electronical box
-
Check connections
Change the electronical box
Eficiency reduction of the massage
Jet clogged or dirty
Clean
-
Equipment
Action
Troubleshooting
Possible cause
User solution
Authoritzed technical service
HYDRO
Press hydromassage
push-button with led
Button light OFF and water
massage OFF
Differential switch or magnetothermic OFF
Connect the differential switch or magnetothermic
-
Button light OFF but water
massage ON
Faulty push-button
-
Change the push-button
The hydromassage stopped a few
seconds when starting or during
the process
Incorrect water level
Fill the bathtub above the starting level
-
Faulty level sensor
-
Change level sensor
Faulty electrical box
-
Change the electronical sensor
The button light is ON for a few
seconds but the hydromassage
does not work
No electricity current at the whirlpool pump
-
Check connections and measure the whirlpool pump
input (230 VAC). Change if necessary.
Problem with the whirpool pump
-
Check connections and measure the whirlpool pump
input (230 VAC)
Check the noise
Change the whirlpool pump (If applicable)
Problem with the electronical box
-
Check connections
Change the electronical box
Efficiency reduction of the
hydromassage
Jet/vacuum protection cover clogged or dirty
Clean
-
Содержание FUSION