nodon CRC-3-6 Скачать руководство пользователя страница 2

In order to put your Soft Remote into “Gateway” Mode, you just have to add the Soft 

Remote into the gateway’s Z-Wave

®

 network. Procedure as following:

1

Place your home automation gateway into “Inclusion” Mode. To do so, please 

refer to your gateway’s user guide.

2

Simultaneously push on 

I

 and 

P

, during 1sec. 

The LED glows in pink to confirm the selection 

3

Push on 

I

, within 10 seconds. 

The LED blinks in pink to confirm your choice

The LED blinks in green to confirm the procedure

 Warning 

: If your Soft Remote added some devices in “Standalone” Mode, these devices will remain 

orphans. Make sure you remove (or reset) all devices previously added or associated into the Soft 

Remote’s network, before placing the Soft Remote in “Gateway” Mode. 

If your home automation gateway supports the “ Controller shift” feature, you can 

recover the existing Soft Remote’s network (while it is in “Standalone” Mode) when 

you pass into “Gateway” Mode. 

Your home automation gateway will be added into the Soft Remote’s network, and 

set  as  the  main  controller.  All  the  information  related  to  the  added  devices  will 

be  automatically  copied  to  the  home  automation  gateway  during  this  process. 

However, all existing association between the Soft Remote and devices will be lost, 

and would need to be set-up again, using your home automation gateway interface.

The existing network of the gateway will be lost as well.

The procedure is as following:

1

Place your home automation gateway into “Learning” Mode. To do so, please 

refer to your gateway’s user guide. 

2

Simultaneously push on 

I

 and 

P

, during 1sec. 

The LED glows in pink to confirm the selection 

3

Push on 

P

, within 10 seconds.

The LED blinks in pink to confirm your choice

The LED blinks in green to confirm the procedure

REMOVE THE Soft Remote FROM THE NETWORK

In order to remove the Soft Remote from the gateway’s Z-Wave

®

 network:

1

Place  your  gateway  into  “Exclusion”  Mode.  To  do  so,  please  refer  to  your 

gateway’s user guide.

2

Simultaneously push on 

I

 and 

P

, during 1sec. 

The LED glows in pink to confirm the selection 

3

Push on 

I

, within 10 seconds.

The LED blinks in pink to confirm your choice

The LED blinks in green to confirm the procedure

Expert Note: It is possible to send just a single NIF by following this procedure:

1

 Simultaneously push on 

I

 and 

P

, during 1sec 

The LED glows in pink to confirm the selection

2

Push on 

O

, within 10 seconds

The LED blinks in pink to confirm your choice

“GATEWAY MODE” FEATURES

 Warning 

: Make sure your gateway supports all the features of the Soft Remote (compatible gateways 

are listed on www.nodon.fr/en ).

INCLUSION ON BEHALF OF THE GATEWAY

1

Push 3 times (quickly) on the 

I

 button.

The LED blinks in blue 

2

Place the device you want to add in “Learning” Mode, within 10 seconds. To do so, 

please refer to your device’s user guide.

The LED blinks in green to confirm the inclusion

EXCLUSION ON BEHALF OF THE GATEWAY

1

Push 3 times (quickly) on the 

M

 button.

The LED blinks in blue 

2

Place the device you want to remove in “Learning” Mode, within 10 seconds. To 

do so, please refer to your device’s user guide.

The LED blinks in green to confirm the exclusion

ASSOCIATION GROUPS 

Once set-up through the gateway, association groups allow direct communication 

between the Soft Remote and the Z-Wave

®

 devices you want to control, without 

involving the gateway in the communication.

BUTTON 2 CONFIGURATION

Parameter Number

Default Value

Size

5

0

1 [byte]

To set-up the how button 2 behaves, when set in MONO Profile

Value

Description

0

Control Group 3

1

All Switch ON

2

All Switch OFF

BUTTON 3 CONFIGURATION

Parameter Number

Default Value

Size

6

0

1 [byte]

To set-up the how button 3 behaves, when set in MONO Profile

Value

Description

0

Control Group 4

1

All Switch ON

2

All Switch OFF

BUTTON 4 CONFIGURATION

Parameter Number

Default Value

Size

7

0

1 [byte]

To set-up the how button 4 behaves, when set in MONO Profile

Value

Description

0

Control Group 5

1

All Switch ON

2

All Switch OFF

When  the  selected  profile  is  «  SCENE  »  (default  value),  the  Soft  Remote 

communicates only with the home automation gateway. The user interface of your 

gateway will then allow you to set-up scenes based on which (and which way) you 

press the different buttons. To do so, please refer to your gateway’s user guide.

The different actions that can be handled by the Soft Remote are: 

• Simple press (on 

I

O

P

 or 

M

• Double press (on 

I

O

P

 or 

M

• Long press (on 

I

O

P

 or 

M

)

• Button released (on 

I

O

P

 or 

M

Which makes a total of 16 different actions.

It is strongly advised to use this profile if supported by your gateway.

However, if your home automation gateway does not support these features, you 

can still use association groups and set-up your buttons as 

•  MONO  Profile,  to  control  the  corresponding  group  or  activate  the 

Z-Wave

®

 « All Switch ON » or « All Switch OFF » features.

• DUO Profile, to control the corresponding groups.

LED MANAGEMENT

Parameter Number

Default Value

Size

8

0

1 [byte]

How to set up LED behaviour

Value

Description

0

No LED

1

Flash Blue after button press

2

Blinking to confirm command

3

Both options above (1&2)

Warning 

: In order that the Soft Remote takes into account the update of association groups and/

or configuration parameters just modified through your home automation gateway, it is necessary 

to  wake  it  up.  To  do  so,  press  on  any  button  of  the  Soft  Remote.  The  new  associations  and/or 

configuration parameters will be then effective.

COMMAND CLASS 

The Soft Remote supports the following Command Class:

COMMAND CLASS 

VERSION

All switch*

V1

Application status*

V1

Association

V2

Association Group Information

V1

Basic*

V1

Battery

V1

Central Scene**

V2

Configuration

V1

Device Reset Locally

V1

Manufacturer Specific

V2

Multilevel Switch*

V3

Power Level

V1

Scene Activation*

V1

Version

V2

Wake-Up**

V2

Z-Wave

®

 Plus info**

V2

* Controlled only (not supported)

** Controlled AND supported

LOGOTYPE

This  product  (CRC-3-6)  is  compliant  with  all  relevant  European 

standards.

This product (CRC-3US-6) is compliant with FCC regulation.

This product (CRC-3US-6) is compliant with IC regulation.

When sorting your waste, please observe the disposal regulations in 

force. Please place your waste in the facilities provided for that purpose 

and with all due respect for the environment.

This product must be used indoor only.

This  product  is  compatible  with  Z-Wave

®

  and  Z-Wave  Plus

®

 

protocol.

CONTACT

Manufacturer & Importer :

:

ID-RF SAS

121 rue des Hêtres

45590 St CYR EN VAL (FRANCE)

AFTER SALES

www.nodon.fr section “support”

[email protected]

For user guides in other languages, please visit 

www.nodon.fr/notices

The Soft Remote has 7 associations groups:

Group

Group Name

1

Lifeline

2

Button 1 - Mono - Controlled nodes

3

Button 2 - Mono - Controlled nodes

4

Button 3 - Mono - Controlled nodes

5

Button 4 - Mono - Controlled nodes

6

Button 1&3 - Duo - Controlled nodes

7

Button 2&4 - Duo - Controlled nodes

Group 1 – Lifeline 

Maximum number of devices in group: 1

This group is dedicated for the home automation gateway.

Group 2/3/4/5

Maximum number of devices in group: 8

Devices  associated  in  these  groups  are  controlled  by  the  corresponding  button, 

according to MONO Profile (in the exact same way as « Standalone » Mode).

Group 6/7

Maximum number of devices in group: 8

Devices associated in these groups are controlled by the corresponding buttons, 

according to DUO Profile (in the exact same way as « Standalone » Mode).

CONFIGURATION PARAMETERS 

Buttons’  profile  (MONO/DUO/SCENE),  in  «  Gateway  »  Mode,  are  set-up  through 

several configuration parameters.

BUTTONS 1&3 PROFILE

Parameter Number

Default Value

Size

1

0

1 [byte]

To set-up the profile of buttons 1 & 3

Value

Description

0

SCENE

1

MONO

2

DUO

BUTTONS 2&4 PROFILE

Parameter Number

Default Value

Size

2

0

1 [byte]

To set-up the profile of buttons 2 & 4

Value

Description

0

SCENE

1

MONO

2

DUO

SCENE TYPE

Parameter Number

Default Value

Size

3

0

1 [byte]

To choose the way of sending Scene to the gateway

Value

Description

0

CENTRAL SCENE

1

SCENE ACTIVATION

We strongly advise you to use « CENTRAL SCENE », which is more user-friendly. 

However, some home automation gateways don’t support « CENTRAL SCENE » yet, 

then you can still use the previous standard « SCENE ACTIVATION ». 

The user interface of your gateway will then allow you to set-up scenes.

BUTTON 1 CONFIGURATION

Parameter Number

Default Value

Size

4

0

1 [byte]

To set-up the how button 1 behaves, when set in MONO Profile

Value

Description

0

Control Group 2

1

All Switch ON

2

All Switch OFF

Отзывы: