NOCO Genius Gen Series Скачать руководство пользователя страница 5

EN

Using 12V Lithium.

12V Lithium charge mode is designed for 12-volt lithium-ion batteries only, including lithium iron phosphate.

CAUTION.

 USE THIS MODE WITH EXTREME CARE. THIS MODE SHOULD ONLY BE USED WITH 12-VOLT LITHIUM BATTERIES THAT HAVE A BUILT-IN BATTERY 

MANAGEMENT SYSTEM (BMS). LITHIUM-ION BATTERIES ARE MADE AND CONSTRUCTED IN DIFFERENT WAYS AND SOME MAY OR MAY NOT CONTAIN A BATTERY 

MANAGEMENT SYSTEM (BMS). CONSULT THE LITHIUM BATTERY MANUFACTURER BEFORE CHARGING AND ASK FOR RECOMMENDED CHARGING RATES AND 

VOLTAGES. SOME LITHIUM-ION BATTERIES MAY BE UNSTABLE AND UNSUITABLE FOR CHARGING. 

Force Mode. [Press & Hold for 5 seconds]

Force mode allow the charger to manually begin charging when the connected battery’s voltage is too low to be detected. If battery voltage is too low for the charger 

to detect, press and hold the mode button for 5 seconds to activate Force Mode, then select the appropriate mode. All available modes will flash. Once a charge mode 

is selected, the Charge Mode LED and Charge LED will alternate between each other, indicating Force Mode is active. After five (5) minutes the charger will return to 

the normal charge operation and low voltage detection will be reactivated.

CAUTION.

 USE THIS MODE WITH EXTREME CARE. FORCE MODE DISABLES SAFETY FEATURES AND LIVE POWER IS PRESENT AT THE CONNECTORS. ENSURE ALL 

CONNECTIONS ARE MADE PRIOR TO ENTERING FORCE MODE, AND DO NOT TOUCH CONNECTIONS TOGETHER. RISK OF SPARKS, FIRE, EXPLOSION, PROPERTY 

DAMAGE, INJURY, AND DEATH.

Using 12V Repair. [From Standby Press and Hold 3 Seconds With Clamps Connected to the Battery]

12V Repair is an advanced battery recovery mode for repairing and storing, old, idle, damaged, stratified or sulfated batteries. Not all batteries can be recovered. 

Batteries tend to become damaged if kept at a low charge and/or never given the opportunity to receive a full charge. The most common battery problems are battery 

sulfation and stratification. Both battery sulfation and stratification will artificially raise the open circuit voltage of the battery, causing the battery to appear fully 

charged, while providing low capacity. Use 12V Repair in attempt to reverse these problems. For optimal results, take the 12-volt battery through a full charge cycle, 

bringing the battery to full charge, before using this mode. 12V Repair can take up to four (4) hours to complete the recovery process and will return to Standby when 

completed.

CAUTION. 

USE THIS MODE WITH CARE. THIS MODE IS FOR 12-VOLT LEAD-ACID BATTERIES ONLY. THIS MODE USES A HIGH CHARGING VOLTAGE AND MAY CAUSE 

SOME WATER LOSS IN WET (FLOODED) CELL BATTERIES. BE ADVISED, SOME BATTERIES AND ELECTRONICS MAY BE SENSITIVE TO HIGH CHARGING VOLTAGES. TO 

MINIMIZE RISKS TO ELECTRONICS, DISCONNECT THE BATTERY BEFORE USING THIS MODE.

Содержание Gen Series

Страница 1: ...heat and is capable of causing burns Do not cover product Do not smoke or use any source of electrical spark or fire when operating product Keep product away from combustible materials Eye Injury Wear...

Страница 2: ...rchaser who agrees to indemnify NOCO for any unintended use or misuse by a minor Choking Hazard Accessories may present a choking hazard to children Do not leave children unattended with product or an...

Страница 3: ...ailure of the product could lead to injury death or severe environmental damage Radio Frequency Interference Product is designed tested and manufactured to comply with regulations governing radio freq...

Страница 4: ...ed charge mode will then operate under Force Mode for five 5 minutes before returning to standard charging in the selected mode 5A Up To 120Ah Batteries Force Mode Press Hold 5 Seconds An advanced bat...

Страница 5: ...LIVE POWER IS PRESENT AT THE CONNECTORS ENSURE ALL CONNECTIONS ARE MADE PRIOR TO ENTERING FORCE MODE AND DO NOT TOUCH CONNECTIONS TOGETHER RISK OF SPARKS FIRE EXPLOSION PROPERTY DAMAGE INJURY AND DEA...

Страница 6: ...gative first or positive first for positive ground systems Begin Charging 1 Verify the voltage and chemistry of the battery 2 Confirm that you have connected the battery clamps or eyelet terminal conn...

Страница 7: ...ged battery and is for reference purposes only Actual data may differ due to battery conditions The time to charge a normally discharged battery is based on a 50 DOD Temperature will also impact charg...

Страница 8: ...arged When the battery is 25 charged the 25 LED will go solid and the next LED will begin to pulse The 75 Charge LED will slowly pulse on and off when the battery is 50 75 charged When the battery is...

Страница 9: ...dicates the Charge Mode the charger is currently in Push the MODE button to cycle through charge Modes 1 Mode Button Push to cycle through charging Modes 2 Overvoltage Error LED Illuminates solid Red...

Страница 10: ...17 Pounds 120 240 VAC 50 60Hz 120 240 VAC 50 60Hz 72x3 W Max Various 5Ax3 12V 1V 12V 0 5mA 20 C to 50 C 12V Wet Gel MF CA EFB AGM Calcium Lithium 3 Up to 120Ah Maintains All Battery Sizes IP68 Natura...

Отзывы: