8m

Use the remote controller within a distance of 8 

meters from the appliance, pointing it towards the 

receiver. Reception is confirmed by a beep.

The remote controller can be attached to a wall or pillar

by using a remote controller holder(not supplied,

purchased separately).

Before installing the remote controller, check that the

air conditioner receives the signals properly.

Install the remote controller with two screws.

For installing or removing the remote controller, move

it up or down in the holder.

The following cases signify exhausted batteries.

Replace old batteries with new ones.

   Receiving beep is not emitted when a signal

    is transmitted.

    Indicator fades away.

Location of the remote controller.

Using the remote controller holder(optional)

The remote controller is powed by two dry 

batteries (R03/LR03X2) housed in the back rear 

part and protected by a cover.

(1) Remove the cover in the rear part of the

remote controller.

(2) Remove the old batteries and insert the new

batteries,placing the(+) and (-) ends correctly.

(3) Install the cover back on.

NOTE: 

When the batteries are removed, the 

remote controller erases all programming.  After 

inserting new batteries, the remote controller 

must be reprogrammed.

Replacing batteries

CAUTIONS

The air conditioner will not operate if curtains, 

doors or other materials block the signals from 

the remote controller to the indoor unit.

Prevent any liquid from falling into the remote 

controller. Do not expose the remote controller 

to direct sunlight or heat.

If the infrared signal receiver on the indoor unit 

is exposed to direct sunlight, the air conditioner 

may not function properly. Use curtains to 

prevent the sunlight from falling on the receiver.

If other electrical appliances react to the remote 

controller, either move these appliances or 

consult your local dealer.

Do not drop the remote controller. Handle with care.

Do not place heavy objects on the remote controller,

or step on it.

CAUTIONS

Do not mix old and new batteries or batteries 

of different types.

Do not leave the batteries in the remote 

controller if they are not going to be used for 

2 or 3 months.

Do not dispose batteries as unsorted 

municipal waste. Collection of such waste 

separately for special treatment is necessary.

Handling the remote controller

13

14

Содержание NBO3-09?DU

Страница 1: ...el Split de Perete Wall Mounted Air Conditioning Unit Aer Conditonat model Split de Perete For correct use of this unit please read this manual carefully and keep it for future reference Pentru o util...

Страница 2: ...ture there is no corresponding operation happened when press the relative button on the remote controller When there are wide differences between Remote controller Illustration and USER S MANUAL on fu...

Страница 3: ...the current operation settings including operating mode setting temperature fan speed level and sleep feature if activated UP Button Push this button to decrease the indoor o o temperature setting in...

Страница 4: ...tation But during the actual operation only the relative functional signs are shown on the display window Displayed when TIMER ON time is set Displayed in Sleep Mode operation Indicated that the air c...

Страница 5: ...art the air conditioner 1 In the Auto mode the air conditioner can logically choose the mode of Cooling Fan and Heating by sensing the difference between the actual ambient room temperature and the se...

Страница 6: ...e TIMER OFF there will be a one second delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal H will disappear and the set...

Страница 7: ...lay 5 Wait for 3 seconds and the digital display area will show the temperature again The TIMER ON OFF indicator remains on and this function is activated TIMER OFF TIMER ON On Stop Start operation Th...

Страница 8: ...over back on NOTE When the batteries are removed the remote controller erases all programming After inserting new batteries the remote controller must be reprogrammed Replacing batteries CAUTIONS The...

Страница 9: ...1 2 8m 3 0V 03 L 03 2 C 60C T 2 3 6 8 8 9 13 MODE FAN TEMP SLEEP TURBO SWING DIRECT LED ON OFF SHORT CUT TIMER ON TIMER OFF RG57B BGE...

Страница 10: ...HIGH 8 10 11 9 6 MODE FAN TEMP ON OFF SHORT CUT TIMER ON TIMER OFF 1 2 4 3 9 10 8 6 11 12 14 RG57B BGE SLEEP TURBO SWING DIRECT LED MODE FAN TEMP ON OFF SHORT CUT TIMER ON TIMER OFF 1 2 4 3 9 10 8 6...

Страница 11: ...12 14 5 6 MODE FAN TEMP ON OFF SHORT CUT TIMER ON TIMER OFF 1 2 4 3 9 10 8 6 11 12 SLEEP TURBO SWING DIRECT LED 14 RG57D BGE...

Страница 12: ...EMP ON OFF SHORT CUT TIMER ON TIMER OFF 4 1 3 2 MODE FAN TEMP ON OFF SHORT CUT TIMER ON TIMER OFF 3 1 2 MODE FAN TEMP ON OFF SHORT CUT TIMER ON TIMER OFF 3 1 2 SLEEP TURBO SWING DIRECT LED SLEEP TURBO...

Страница 13: ...7 0 7 5 8 0 8 5 9 0 9 5 10 11 12 13 14 15 16 17 18 19 20 21 22 23 and 24 mer 9 10 TIMER ON TIMER ON 3 TIMER ON TIMER OFF TIMER OFF TIMER OFF 3 TIMER OFF TIMER TIMER ON 2 1 MODE FAN TEMP ON OFF SHORT...

Страница 14: ...11 12 11 12...

Страница 15: ...8m 13 14...

Страница 16: ...at Dac unitatea nu are aceast func ie nu va exista nici o opera iune corespunz toare atunci c nd ap sa i tasta de pe telecomand Atunci c nd exist diferen e mari ntre Manual Telecomenzii i Manualul de...

Страница 17: ...sta PORNIT OPRIT Tasta PORNIRE PROGRAMARE Tasta OPRIRE PROGRAMARE Tasta VENTILARE Tasta TURBO MODE FAN TEMP ON OFF SHORT CUT TIMER ON TIMER OFF 1 2 4 3 9 10 8 6 11 12 14 RG57B BGE SLEEP TURBO SWING DI...

Страница 18: ...e afiseaza cand se trimite semnalul Se afiseaza cand telecomanda este pornita Afisaj baterie detectare baterie descarcata Nu este disponibil pentru acest aparat Se afiseaza cand Pornirea Programata es...

Страница 19: ...sau VENTILARE 2 A i butoanele sus pentru a seta temperatura dorit 3 A i butonul VENTILARE pentru a selecta vit ventilatorului n patru trepte Auto Mica Medie sau Mare 4 A i butonul PORNIT OPRIT pentru...

Страница 20: ...amre 9 10 Functia de Programare Setare pornirii programate T 3 o Setare opririi programate T 3 Exemplu PORNIRE PROGRAMATA Pornire Auto 2 1 MODE FAN TEMP ON OFF SHORT CUT TIMER ON TIMER OFF SLEEP TURBO...

Страница 21: ...ziu dupa setare Pornire Pornit Setare 10 ore mai tarziu Oprire Auto OPRIRE PROGRAMATA Exemplu Exemplu OPRIRE PROGRAMATA PORNIRE PROGRAMATA Pornit Oprit Pornire functionare TIMP COMBINAT Setarea pornir...

Страница 22: ...8m Pozitionarea telecomenzii Inlocuirea bateriilor Manevrarea telecomenzii 13 14 Folosirea suportului de telecomanda optional...

Отзывы: