OPERATION
Falcon
t
Ultra B (07--05)
11
4. Connect solution hose to accessory tool coupler,
located at lower rear of machine (Figure 11).
FIG. 11
5. Connect accessory tool to solution hose and
vacuum hose (Figure 12).
FIG. 12
6. Turn on main, pump and vacuum switches.
7. Take accessory tool and begin cleaning at top of
area and work backwards toward machine.
WARNING: Fire Or Explosion Hazard. Do Not
Pick Up Flammable Materials Or Reactive Metals.
8. Place accessory tool head on area to be cleaned;
squeeze trigger, apply downward pressure on
accessory tool head, and slowly pull tool
backwards. Release trigger 152 mm (6 in) from
end of stroke (Figure 13).
FIG. 13
9. When returning for next stroke, push accessory
tool forward over same path with trigger released.
Continue this pull and push method with a 50 to
102 mm (2 to 4 in) overlap of each stroke.
NOTE:
For heavily soiled areas, repeat stroke or
change angle of stroke.
10. Empty recovery tank when solution tank runs dry
(See DRAINING TANKS)
.
ATTENTION: Do not allow foam to enter the float
shut-off screen, vacuum motor damage will result.
Foam will not activate the float shut-off screen.
DRAINING TANKS
The recovery tank should be drained and cleaned out
after every use. The solution tank should be cleaned
out periodically to remove any corrosion.
Transport the machine to a draining site, turn machine
off and follow the draining instructions below:
ATTENTION: Raise brush/pick-up head when
transporting machine to floor drain.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off machine.