etc.
These frequencies (16, 32, 48, 64 Khz), are not really intended to be a part of the 60 Hz (in this
example) AC that is provided by the Inverter. They are a a side effect. They represent DE.
3.2 Introduction To Reducing The Dirty Electricity From Inverters
The aforementioned parallel DNA products can be used to reduce the DE from alternative energy
systems, specifically the Inverter(s) that are an integral part of the system. In this approach,
laboratory test have typically shown a reduction of 10-to-1 of the DE.
In the case of alternative power, there can be Inverters that are supplying 1000's of watts of power
from the solar or wind devices. The DE from an Inverter can be considerable, and the reduction of a
parallel device (such as a MxDNA, RxDNA-V2, PxDNA) may not reduce the DE to a value that is
acceptable to the User (in the residential, commercial or industrial setting).
The product that we offer to accomplish a large reduction of the DE from alternative energy systems
is a "line filter" device, aka "inline filter". It is the DNA Line Filter.
While the aforementioned parallel products have the considerable convenience of the user simply
"plugging them in", the DNA Line Filter requires a professional electrician to install them.
The DNA-Line Filter will be connected between the Inverter and the users power wiring. The DNA
Line Filter will very effectively reduce the DE from the Inverter.
As a point of comparison, the parallel devices (
MxDNA, RxDNA-V2, PxDNA
) have been tested
and typically reduce the DE,
10-to-1
.
DNA Line Filter
testing shows typical reduction
of 500-to-1
at 16 Khz and greater reductions at
higher frequencies.
3.3 Detailed Description of Using DNA Line Filter to reduce Solar/Wind Inverter Dirty
Electricity
Now, specifically referring to the application of the DNA Line Filters, many solar array / wind
installations in the US are configured with the Inverter supplying 240 VAC with 2 Hot lines and 1
Neutral line. If a DNA Line Filter is being used to reduce DE from the Inverter Output, then 2
approaches can be used:
–
Use 2 each of the single phase DNA Line Filter products
–
Use 1 each of the dual phase DNA Line Filter products
Detailed connection diagram are included in the next major document section, 5.0
Not all solar/wind installations in the US are 2 phase (2 Leg). In some cases there is a single phase
power circuit, usually 5 KW or less. In thse cases, a single phase DNA Line Filter is used.
3